Correlation between Blood Flow and Temperature of the Ocular Anterior Segment in Normal Subjects

作者: Takashi Itokawa , Takashi Suzuki , Yukinobu Okajima , Tatsuhiko Kobayashi , Hiroko Iwashita

DOI: 10.3390/DIAGNOSTICS10090695

关键词:

摘要: Purpose: To determine a correlation between temperature and blood flow in the ocular anterior segment, their effects on corneal temperature. Methods: In experiment 1, we recruited 40 eyes measured anterior-segment (upper/lower eyelid skin, palpebral bulbar conjunctiva, cornea) before after application of warm compresses. 2, 20 same tissues during stimulation using water capsaicin solution oral cavity. Results: temperatures upper/lower skin cornea increased significantly until 15 min compress; conjunctiva 10 min. The min, that were correlated with upper lower conjunctiva. all locations conjunctival contributed independently to Conclusions: significantly,

参考文章(51)
Robin M. McAllen, Michael J. McKinley, Efferent thermoregulatory pathways regulating cutaneous blood flow and sweating Handbook of Clinical Neurology. ,vol. 156, pp. 305- 316 ,(2018) , 10.1016/B978-0-444-63912-7.00018-7
Tetsuji Nakamoto, Masato Kanao, Yusuke Kondo, Norihiro Kajiwara, Chihiro Masaki, Tetsu Takahashi, Ryuji Hosokawa, Two-dimensional real-time blood flow and temperature of soft tissue around maxillary anterior implants. Implant Dentistry. ,vol. 21, pp. 522- 527 ,(2012) , 10.1097/ID.0B013E318272FE81
Kenji Toba, Yasuyoshi Ouchi, Masahiro Akishita, Koichi Kozaki, Michiro Ishikawa, Koichiro Nagano, Masato Etoh, Masayoshi Hashimoto, Jing Liang, Namiki Ueda, Hajime Orimo, Improved skin blood flow and cutaneous temperature in the foot of a patient with arteriosclerosis obliterans by vasopressin V1 antagonist (OPC21268). A case report. Angiology. ,vol. 46, pp. 1027- 1033 ,(1995) , 10.1177/000331979504601108
Wasineenart Mongkolpun, Diego Orbegozo, Carolina P. R. Cordeiro, Claudio J. C. S. Franco, Jean-Louis Vincent, Jacques Creteur, Alterations in Skin Blood Flow at the Fingertip Are Related to Mortality in Patients With Circulatory Shock. Critical Care Medicine. ,vol. 48, pp. 443- 450 ,(2020) , 10.1097/CCM.0000000000004177
Tomoyuki Kamao, Masahiko Yamaguchi, Shiro Kawasaki, Shiro Mizoue, Atsushi Shiraishi, Yuichi Ohashi, Screening for Dry Eye With Newly Developed Ocular Surface Thermographer American Journal of Ophthalmology. ,vol. 151, pp. 782- 791.e1 ,(2011) , 10.1016/J.AJO.2010.10.033
Giuseppe Giannaccare, Michela Fresina, Luca Agnifili, Piera Versura, Ocular-surface temperature modification by cataract surgery Journal of Cataract and Refractive Surgery. ,vol. 42, pp. 983- 989 ,(2016) , 10.1016/J.JCRS.2016.04.023
Takashi Itokawa, Yukinobu Okajima, Takashi Suzuki, Koji Kakisu, Hiroko Iwashita, Yoshitaka Murakami, Yuichi Hori, Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers. Investigative Ophthalmology & Visual Science. ,vol. 59, pp. 771- 775 ,(2018) , 10.1167/IOVS.17-23173
Takashi Itokawa, Yukinobu Okajima, Takashi Suzuki, Tatsuhiko Kobayashi, Yuto Tei, Koji Kakisu, Yuichi Hori, Association among Blink Rate, Changes in Ocular Surface Temperature, Tear Film Stability, and Functional Visual Acuity in Patients after Cataract Surgery Journal of Ophthalmology. ,vol. 2019, pp. 8189097- ,(2019) , 10.1155/2019/8189097
Philip B. Morgan, Meng Poey Soh, Nathan Efron, Corneal surface temperature decreases with age. Contact Lens and Anterior Eye. ,vol. 22, pp. 11- 13 ,(1999) , 10.1016/S1367-0484(99)80025-3
CHRISTINE PURSLOW, JAMES WOLFFSOHN, The relation between physical properties of the anterior eye and ocular surface temperature. Optometry and Vision Science. ,vol. 84, pp. 197- 201 ,(2007) , 10.1097/OPX.0B013E3180339F6E