Timing readout in paper device for quantitative point-of-use hemin/G-quadruplex DNAzyme-based bioassays

作者: Yun Zhang , Jinlong Fan , Jinfang Nie , Shangwang Le , Wenyuan Zhu

DOI: 10.1016/J.BIOS.2015.04.081

关键词:

摘要: This work describes a quantitative point-of-use hemin/G-quadruplex DNAzyme-based assay that integrates simple timing detection motif with low-cost, portable microfluidic paper-based analytical devices (μPADs). The readout is based on the selective DNAzyme-mediated wettability change of paper from hydrophilicity to hydrophobicity. Its utility well demonstrated sensitive, specific K+ ion as model analyte in artificial samples real human serum samples. new method only requires ubiquitous cheap timer (or cell phone function) provide results. It could offer opportunities for development more peroxidase-mimicking bioassays are simple, affordable, portable, and operable by minimally-trained users broad applications especially resource-poor settings.

参考文章(62)
Lab on paper Lab on a Chip. ,vol. 8, pp. 1988- 1991 ,(2008) , 10.1039/B814043J
R. R. Breaker, Making Catalytic DNAs Science. ,vol. 290, pp. 2095- 2096 ,(2000) , 10.1126/SCIENCE.290.5499.2095
Zhengbo Chen, Yanqin Huang, Xiaoxiao Li, Tong Zhou, He Ma, Hong Qiang, Yifei Liu, Colorimetric detection of potassium ions using aptamer-functionalized gold nanoparticles Analytica Chimica Acta. ,vol. 787, pp. 189- 192 ,(2013) , 10.1016/J.ACA.2013.05.020
Jingyun Wang, Maria Rowena N. Monton, Xi Zhang, Carlos D. M. Filipe, Robert Pelton, John D. Brennan, Hydrophobic sol–gel channel patterning strategies for paper-based microfluidics Lab on a Chip. ,vol. 14, pp. 691- 695 ,(2014) , 10.1039/C3LC51313K
Peiwen Wu, Kevin Hwang, Tian Lan, Yi Lu, None, A DNAzyme-gold nanoparticle probe for uranyl ion in living cells. Journal of the American Chemical Society. ,vol. 135, pp. 5254- 5257 ,(2013) , 10.1021/JA400150V
Li Hou, Zhuangqiang Gao, Mingdi Xu, Xia Cao, Xiaoping Wu, Guonan Chen, Dianping Tang, DNAzyme-functionalized gold-palladium hybrid nanostructures for triple signal amplification of impedimetric immunosensor. Biosensors and Bioelectronics. ,vol. 54, pp. 365- 371 ,(2014) , 10.1016/J.BIOS.2013.11.014
A. Verdian-Doghaei, M.R. Housaindokht, Kh. Abnous, A fluorescent aptasensor for Potassium ion detection based triple-helix molecular switch Analytical Biochemistry. ,vol. 466, pp. 72- 75 ,(2014) , 10.1016/J.AB.2014.08.014
Xu-Hua Zhao, Liang Gong, Xiao-Bing Zhang, Bin Yang, Ting Fu, Rong Hu, Weihong Tan, Ruqin Yu, Versatile DNAzyme-Based Amplified Biosensing Platforms for Nucleic Acid, Protein, and Enzyme Activity Detection Analytical Chemistry. ,vol. 85, pp. 3614- 3620 ,(2013) , 10.1021/AC303457U
Feng Li, Limin Yang, Mingqin Chen, Yi Qian, Bo Tang, A novel and versatile sensing platform based on HRP-mimicking DNAzyme-catalyzed template-guided deposition of polyaniline. Biosensors and Bioelectronics. ,vol. 41, pp. 903- 906 ,(2013) , 10.1016/J.BIOS.2012.09.048
Boram Kim, In Hwan Jung, Mijeong Kang, Hong-Ku Shim, Han Young Woo, Cationic Conjugated Polyelectrolytes-Triggered Conformational Change of Molecular Beacon Aptamer for Highly Sensitive and Selective Potassium Ion Detection Journal of the American Chemical Society. ,vol. 134, pp. 3133- 3138 ,(2012) , 10.1021/JA210360V