Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography

作者: Philip A. Araoz , Jacobo Kirsch , Andrew N. Primak , Natalie N. Braun , Osama Saba

DOI: 10.1007/S10554-009-9489-3

关键词:

摘要: The purpose of this study was to determine the cardiac phase having highest coronary sharpness for low and high heart rate patients scanned with dual source CT (DSCT) compare image over different phases. DSCT scans 30 (≤70 beats per minute- bpm) (>70 were reconstructed into phases, starting at 30% increasing 5% increments until 70%. A blinded observer graded segment, from which scores produced right (RCA), left main (LM), anterior descending (LAD), circumflex (Cx) arteries. For each artery, maximal identified repeated measures analysis variance. Comparison between made using generalized estimating equations. rates all four vessels (RCA, LM, LAD, Cx) 65 or 70% phase, are end-diastolic 35 45% end-systolic Low had higher most phases; however, in (P < 0.0001). Using scanning, optimal is obtained end-diastole end-systole rates.

参考文章(13)
Paul Stolzmann, Hans Scheffel, Thomas Schertler, Thomas Frauenfelder, Sebastian Leschka, Lars Husmann, Thomas G. Flohr, Borut Marincek, Philipp A. Kaufmann, Hatem Alkadhi, Radiation dose estimates in dual-source computed tomography coronary angiography European Radiology. ,vol. 18, pp. 592- 599 ,(2008) , 10.1007/S00330-007-0786-8
Bernd J. Wintersperger, Konstantin Nikolaou, Franz von Ziegler, Thorsten Johnson, Carsten Rist, Alexander Leber, Thomas Flohr, Andreas Knez, Maximilian F. Reiser, Christoph R. Becker, Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Investigative Radiology. ,vol. 41, pp. 436- 442 ,(2006) , 10.1097/01.RLI.0000202639.99949.C6
Sebastian Leschka, Hans Scheffel, Lotus Desbiolles, Andre Plass, Oliver Gaemperli, Ines Valenta, Lars Husmann, Thomas G. Flohr, Michele Genoni, Borut Marincek, Philipp A. Kaufmann, Hatem Alkadhi, Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Investigative Radiology. ,vol. 42, pp. 543- 549 ,(2007) , 10.1097/RLI.0B013E31803B93CF
Annick C. Weustink, Willem B. Meijboom, Nico R. Mollet, Masato Otsuka, Fransesca Pugliese, Carlos van Mieghem, Roberto Malago, Niels van Pelt, Marcel L. Dijkshoorn, Filippo Cademartiri, Gabriel P. Krestin, Pim J. de Feyter, Reliable high-speed coronary computed tomography in symptomatic patients. Journal of the American College of Cardiology. ,vol. 50, pp. 786- 794 ,(2007) , 10.1016/J.JACC.2007.04.068
Martin Heuschmid, Christof Burgstahler, Anja Reimann, Harald Brodoefel, Ines Mysal, Ellen Haeberle, Ilijas Tsiflikas, Claus D. Claussen, Andreas F. Kopp, Stephen Schroeder, Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease. American Journal of Cardiology. ,vol. 100, pp. 587- 592 ,(2007) , 10.1016/J.AMJCARD.2007.03.066
Sebastian Leschka, Simon Wildermuth, Thomas Boehm, Lotus Desbiolles, Lars Husmann, André Plass, Pascal Koepfli, Tiziano Schepis, Borut Marincek, Philipp A. Kaufmann, Hatem Alkadhi, Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology. ,vol. 241, pp. 378- 385 ,(2006) , 10.1148/RADIOL.2412051384
Thomas G. Flohr, Cynthia H. McCollough, Herbert Bruder, Martin Petersilka, Klaus Gruber, Christoph Süβ, Michael Grasruck, Karl Stierstorfer, Bernhard Krauss, Rainer Raupach, Andrew N. Primak, Axel Küttner, Stefan Achenbach, Christoph Becker, Andreas Kopp, Bernd M. Ohnesorge, First performance evaluation of a dual-source CT (DSCT) system. European Radiology. ,vol. 16, pp. 256- 268 ,(2006) , 10.1007/S00330-005-2919-2
Annick C. Weustink, Nico R. Mollet, Francesca Pugliese, Willem B. Meijboom, Koen Nieman, Majanka H. Heijenbrok-Kal, Thomas G. Flohr, Lisanne A. E. Neefjes, Filippo Cademartiri, Pim J. de Feyter, Gabriel P. Krestin, Optimal Electrocardiographic Pulsing Windows and Heart Rate: Effect on Image Quality and Radiation Exposure at Dual-Source Coronary CT Angiography Radiology. ,vol. 248, pp. 792- 798 ,(2008) , 10.1148/RADIOL.2483072098
Lars Husmann, Sebastian Leschka, Lotus Desbiolles, Tiziano Schepis, Oliver Gaemperli, Burkhardt Seifert, Philippe Cattin, Thomas Frauenfelder, Thomas G. Flohr, Borut Marincek, Philipp A. Kaufmann, Hatem Alkadhi, Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate—Implications for CT Image Reconstruction Radiology. ,vol. 245, pp. 567- 576 ,(2007) , 10.1148/RADIOL.2451061791
Sebastian Leschka, Lars Husmann, Lotus M. Desbiolles, Oliver Gaemperli, Tiziano Schepis, Pascal Koepfli, Thomas Boehm, Borut Marincek, Philipp A. Kaufmann, Hatem Alkadhi, Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT European Radiology. ,vol. 16, pp. 1964- 1972 ,(2006) , 10.1007/S00330-006-0262-X