摘要: A new Intervertebral Motion Device (IMD) was developed in this study. Depending on its configuration, the IMD used to measure motion sagittal, frontal, and transverse planes. Calibration results showed that root-mean-square (RMS) error of 0.092 mm axial translation, 0.065 shear 0.091 rotation. Using IMD, nine intact human lumbosacral spine specimens (L3-S1) were tested under a simulated physiological load an MTS (Model 858 Bionix, System Corporation Minneapolis, MN). The ranges (ROMs) instrumented measured terms angular (main motion) coupled translation sagittal plane, plane. demonstrated fusion with CS instrumentation at level L4-L5 significantly decreased ROMs for all main motions (P < 0.03). application CD rods had less influence ROM L/R rotation compared Flex/Ext lateral bending.

参考文章(32)
Manohar M. Panjabi, Wayne O. Southwick, Martin H. Krag, Augustus A. White, Effects of preload on load displacement curves of the lumbar spine. Orthopedic Clinics of North America. ,vol. 8, pp. 181- 192 ,(1977) , 10.1016/S0030-5898(20)30944-5
Sypert Gw, Low back pain disorders: lumbar fusion? Clinical neurosurgery. ,vol. 33, pp. 457- ,(1986)
Dennis J. Maiman, R. W. Jodat, Joseph F. Cusick, Joel B. Myklebust, Anthony Sances, S. J. Larson, The biomechanics of spinal injuries. Critical Reviews in Biomedical Engineering. ,vol. 11, pp. 1- 76 ,(1984)
Mimura M, [Rotational instability of the lumbar spine--a three-dimensional motion study using bi-plane X-ray analysis system]. The Journal of the Japanese Orthopaedic Association. ,vol. 64, pp. 546- ,(1990)
M M Panjabi, T R Oxland, I Yamamoto, J J Crisco, Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves Journal of Bone and Joint Surgery, American Volume. ,vol. 76, pp. 413- 424 ,(1994) , 10.2106/00004623-199403000-00012
Daniel HK Chow, Keith DK Luk, John H Evans, John CY Leong, None, Effects of Short Anterior Lumbar Interbody Fusion on Biomechanics of Neighboring Unfused Segments Spine. ,vol. 21, pp. 549- 555 ,(1996) , 10.1097/00007632-199603010-00004
Stephen I. Esses, Brian J. Doherty, Matthew J. Crawford, Vadim Dreyzin, Kinematic Evaluation of Lumbar Fusion Techniques Spine. ,vol. 21, pp. 676- 684 ,(1996) , 10.1097/00007632-199603150-00003
MARK PEARCY, IAN PORTEK, JANIS SHEPHERD, Three-dimensional x-ray analysis of normal movement in the lumbar spine. Spine. ,vol. 9, pp. 294- 297 ,(1984) , 10.1097/00007632-198404000-00013
SAI WEI YANG, NOSHIR A. LANGRANA, CASEY K. LEE, Biomechanics of lumbosacral spinal fusion in combined compression-torsion loads. Spine. ,vol. 11, pp. 937- 941 ,(1986) , 10.1097/00007632-198611000-00014