摘要: Purpose To develop and demonstrate the feasibility of a silent respiratory navigator technique for prospective triggering, which was incorporated into three-dimensional radial zero-echo-time sequence navigated abdominal imaging. Methods A nonselective hard excitation radiofrequency pulse used with derated readout gradient, to avoid generation high levels acoustic noise. The acquired signals were processed in real time triggering sequence. Ten healthy volunteers scanned using proposed conventional techniques at 1.5 T. An noise measurement A-weighted continuous equivalent sound pressure level also performed. Results The pressure–level values background noise, imaging, conventional, navigators 68.3, 68.4, 102.5, 69.4 dBA, respectively. Excellent correlation coefficients greater than 0.9 observed between bellows displacement calculated from navigators. Sharpness portal vein both navigator–triggered images significantly higher those nontriggered images. Conclusions The is feasible might improve image quality workflow MRI patients who are prone Magn Reson Med, 2017. © 2017 International Society Magnetic Resonance Medicine.

参考文章(34)
Florian Wiesinger, Laura I. Sacolick, Anne Menini, Sandeep S. Kaushik, Sangtae Ahn, Patrick Veit-Haibach, Gaspar Delso, Dattesh D. Shanbhag, Zero TE MR bone imaging in the head. Magnetic Resonance in Medicine. ,vol. 75, pp. 107- 114 ,(2016) , 10.1002/MRM.25545
Yuji Iwadate, Anja C. S. Brau, Shreyas S. Vasanawala, Hiroyuki Kabasawa, Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme. Magnetic Resonance in Medicine. ,vol. 72, pp. 172- 177 ,(2014) , 10.1002/MRM.24902
Jianing Pang, Himanshu Bhat, Behzad Sharif, Zhaoyang Fan, Louise E. J. Thomson, Troy LaBounty, John D. Friedman, James Min, Daniel S. Berman, Debiao Li, Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM). Magnetic Resonance in Medicine. ,vol. 71, pp. 67- 74 ,(2014) , 10.1002/MRM.24628
Markus Weiger, Klaas P. Pruessmann, Franciszek Hennel, MRI with zero echo time: Hard versus sweep pulse excitation Magnetic Resonance in Medicine. ,vol. 66, pp. 379- 389 ,(2011) , 10.1002/MRM.22799
Yi Wang, Roger C. Grimm, Joel P. Felmlee, Sephen J. Riederer, Richard L. Ehman, Algorithms for extracting motion information from navigator echoes Magnetic Resonance in Medicine. ,vol. 36, pp. 117- 123 ,(1996) , 10.1002/MRM.1910360120
Julian Maclaren, Michael Herbst, Oliver Speck, Maxim Zaitsev, Prospective motion correction in brain imaging: A review Magnetic Resonance in Medicine. ,vol. 69, pp. 621- 636 ,(2013) , 10.1002/MRM.24314
Peng Lai, Andrew C. Larson, Jaeseok Park, James C. Carr, Debiao Li, Respiratory Self-Gated Four-Dimensional Coronary MR Angiography: A Feasibility Study Magnetic Resonance in Medicine. ,vol. 59, pp. 1378- 1385 ,(2008) , 10.1002/MRM.21617
Fabio Gibiino, Laura Sacolick, Anne Menini, Luigi Landini, Florian Wiesinger, Free-breathing, zero-TE MR lung imaging Magnetic Resonance Materials in Physics Biology and Medicine. ,vol. 28, pp. 207- 215 ,(2015) , 10.1007/S10334-014-0459-Y
Debiao Li, Himanshu Bhat, Lan Ge, Sonia Nielles-Vallespin, Sven Zuehlsdorff, 3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiency Magnetic Resonance in Medicine. ,vol. 65, pp. 1269- 1277 ,(2011) , 10.1002/MRM.22717