Improving the Imaging of Small High-Density Structures in Computed Tomography

作者: M.E. Rollano Hijarrubia

DOI:

关键词:

摘要: textabstractComputed Tomography (CT) imaging of small high-density structures such as calcifications and stents is highly relevant in diagnosis, treatment planning, follow-up of patients with cardiovascular disease. Calcification quantification increasingly used as a potential marker for However, owing to image blur, accurate calcification compromised. In addition, blur high intensity structures hampers the visualization surrounding soft tissue structures. This example affects the assessment degree vessel stenoses at locations close calcified atherosclerotic plaques and/or stent struts. The research described this thesis focuses on improved density structures, in particular calcifications.

参考文章(81)
George M. Martin, Correspondence The American Journal of Pathology. ,vol. 153, pp. 1319- 1320 ,(1998) , 10.1016/S0002-9440(10)65677-5
Joachim E. Wildberger, Andreas H. Mahnken, Thomas Flohr, Rainer Raupach, Claudia Weiss, Rolf W. Günther, Stefan Schaller, Spatial domain image filtering in computed tomography: feasibility study in pulmonary embolism. European Radiology. ,vol. 13, pp. 717- 723 ,(2003) , 10.1007/S00330-002-1700-Z
Stefan Ulzheimer, Willi A. Kalender, Assessment of calcium scoring performance in cardiac computed tomography. European Radiology. ,vol. 13, pp. 484- 497 ,(2003) , 10.1007/S00330-002-1746-Y
Lewis Wexler, Bruce Brundage, John Crouse, Robert Detrano, Valentin Fuster, Jamshid Maddahi, John Rumberger, William Stanford, Richard White, Kathryn Taubert, Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications. A statement for health professionals from the American Heart Association. Writing Group. Circulation. ,vol. 94, pp. 1175- 1192 ,(1996) , 10.1161/01.CIR.94.5.1175
Georg M??hlenbruch, Christoph Thomas, Joachim E. Wildberger, Ralf Koos, Marco Das, Christian Hohl, Marcus Katoh, Rolf W. G??nther, Andreas H. Mahnken, Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo. Investigative Radiology. ,vol. 40, pp. 695- 699 ,(2005) , 10.1097/01.RLI.0000179523.07907.A6
A Polacin, W A Kalender, G Marchal, Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology. ,vol. 185, pp. 29- 35 ,(1992) , 10.1148/RADIOLOGY.185.1.1523331
Harrison H. Barrett, Objective assessment of image quality: Effects of quantum noise and object variability Journal of The Optical Society of America A-optics Image Science and Vision. ,vol. 7, pp. 1266- 1278 ,(1990) , 10.1364/JOSAA.7.001266
Ge Wang, Margaret W. Skinner, Michael W. Vannier, Temporal bone volumetric image deblurring in spiral computed tomography scanning Academic Radiology. ,vol. 2, pp. 888- 895 ,(1995) , 10.1016/S1076-6332(05)80069-8