Evaluation of the variables that affect resolution in delayed extraction MALDI-TOF

作者: Damon C. Barbacci , Ricky D. Edmondson , David H. Russell

DOI: 10.1016/S0168-1176(97)00169-9

关键词:

摘要: Abstract The effects of the various experimental parameters on mass resolution MALDI-TOF and MALDI with delayed extraction are evaluated using an ion flight simulation program. With this program we able to examine initial position, velocity, delay time, kinetic energy line width TOF spectra. A description model is presented as well data showing DE arrival time distribution ions in linear reflectron

参考文章(44)
B.A. Mamyrin, Laser assisted reflectron time-of-flight mass spectrometry International Journal of Mass Spectrometry and Ion Processes. ,vol. 131, pp. 1- 19 ,(1994) , 10.1016/0168-1176(93)03891-O
Randy M. Whittal, Liang. Li, High-resolution matrix-assisted laser desorption/ionization in a linear time-of-flight mass spectrometer. Analytical Chemistry. ,vol. 67, pp. 1950- 1954 ,(1995) , 10.1021/AC00109A007
Arnd Ingendoh, Michael Karas, Franz Hillenkamp, Ulrich Giessmann, Factors affecting the resolution in matrix-assisted laser desorption--ionization mass spectrometry International Journal of Mass Spectrometry and Ion Processes. ,vol. 131, pp. 345- 354 ,(1994) , 10.1016/0168-1176(93)03873-K
Ricky D. Edmondson, David H. Russell, Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass measurement accuracy by using delayed extraction. Journal of the American Society for Mass Spectrometry. ,vol. 7, pp. 995- 1001 ,(1996) , 10.1016/1044-0305(96)00027-X
Mary Gimon-Kinsel, Lisa M. Preston-Schaffter, Gary R. Kinsel, David H. Russell, Effects of Matrix Structure/Acidity on Ion Formation in Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Journal of the American Chemical Society. ,vol. 119, pp. 2534- 2540 ,(1997) , 10.1021/JA960269B
Kuang Jen. Wu, Thomas A. Shaler, Christopher H. Becker, Time-of-Flight Mass Spectrometry Of Underivatized Single-Stranded DNA Oligomers by Matrix-Assisted Laser Desorption Analytical Chemistry. ,vol. 66, pp. 1637- 1645 ,(1994) , 10.1021/AC00082A007
Michael. Karas, Franz. Hillenkamp, Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons Analytical Chemistry. ,vol. 60, pp. 2299- 2301 ,(1988) , 10.1021/AC00171A028
Christopher L. Holliman, Don L. Rempel, Michael L. Gross, Detection of high mass-to-charge ions by Fourier transform mass spectrometry Mass Spectrometry Reviews. ,vol. 13, pp. 105- 132 ,(1994) , 10.1002/MAS.1280130202
Klaus Dreisewerd, Martin Schürenberg, Michael Karas, Franz Hillenkamp, Influence of the laser intensity and spot size on the desorption of molecules and ions in matrix-assisted laser desorption/ionization with a uniform beam profile International Journal of Mass Spectrometry and Ion Processes. ,vol. 141, pp. 127- 148 ,(1995) , 10.1016/0168-1176(94)04108-J