Evolution of a capacitive electromyography contactless biosensor: Design and modelling techniques

作者: Charn Loong Ng , Mamun Bin Ibne Reaz

DOI: 10.1016/J.MEASUREMENT.2019.05.031

关键词:

摘要: Abstract Musculoskeletal disorders (MSDs) and ergonomic issues have long-term impacts on the human body, affecting patient health world’s economy. To address these issues, electromyography (EMG) can provide detailed information of muscular activity during stages diagnosis recovery for general monitoring. The conventional way to extract EMG signals from body requires a professional setup complex post-signal processing may cause side effects subject’s body. This paper focuses two prominent areas: it provides an in-depth analysis signal characteristics, discussion research development hardware contactless biosensor. study extensive review performance comparison capacitive sensors developed by different researchers. It also presents guidelines parameters future researchers comply with in developing practical rugged

参考文章(86)
Bahareh Taji, Shervin Shirmohammadi, Voicu Groza, Izmail Batkin, Impact of Skin–Electrode Interface on Electrocardiogram Measurements Using Conductive Textile Electrodes IEEE Transactions on Instrumentation and Measurement. ,vol. 63, pp. 1412- 1422 ,(2014) , 10.1109/TIM.2013.2289072
Dario Farina, Roberto Colombo, Roberto Merletti, Henrik Baare Olsen, Evaluation of intra-muscular EMG signal decomposition algorithms Journal of Electromyography and Kinesiology. ,vol. 11, pp. 175- 187 ,(2001) , 10.1016/S1050-6411(00)00051-1
R. Paradiso, G. Loriga, N. Taccini, A wearable health care system based on knitted integrated sensors international conference of the ieee engineering in medicine and biology society. ,vol. 9, pp. 337- 344 ,(2005) , 10.1109/TITB.2005.854512
Lena Gourmelon, Geert Langereis, Contactless sensors for Surface Electromyography. international conference of the ieee engineering in medicine and biology society. ,vol. 1, pp. 2514- 2517 ,(2006) , 10.1109/IEMBS.2006.260733
C.R. Merritt, H.T. Nagle, E. Grant, Fabric-Based Active Electrode Design and Fabrication for Health Monitoring Clothing international conference of the ieee engineering in medicine and biology society. ,vol. 13, pp. 274- 280 ,(2009) , 10.1109/TITB.2009.2012408
Carlo J. De Luca, L. Donald Gilmore, Mikhail Kuznetsov, Serge H. Roy, Filtering the surface EMG signal: Movement artifact and baseline noise contamination Journal of Biomechanics. ,vol. 43, pp. 1573- 1579 ,(2010) , 10.1016/J.JBIOMECH.2010.01.027
Ming-Zher Poh, Nicholas C Swenson, Rosalind W Picard, A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity IEEE Transactions on Biomedical Engineering. ,vol. 57, pp. 1243- 1252 ,(2010) , 10.1109/TBME.2009.2038487
Mamun Bin Ibne Reaz, MS Hussain, Faisal Mohd-Yasin, Techniques of EMG signal analysis: detection, processing, classification and applications Biological Procedures Online. ,vol. 8, pp. 11- 35 ,(2006) , 10.1251/BPO115
Mario Cifrek, Vladimir Medved, Stanko Tonković, Saša Ostojić, Surface EMG based muscle fatigue evaluation in biomechanics Clinical Biomechanics. ,vol. 24, pp. 327- 340 ,(2009) , 10.1016/J.CLINBIOMECH.2009.01.010
Carlo J. De Luca, Mikhail Kuznetsov, L. Donald Gilmore, Serge H. Roy, Inter-electrode spacing of surface EMG sensors: reduction of crosstalk contamination during voluntary contractions. Journal of Biomechanics. ,vol. 45, pp. 555- 561 ,(2012) , 10.1016/J.JBIOMECH.2011.11.010