Volume-rendered multidetector CT angiography: noninvasive follow-up of patients treated with renal artery stents.

作者: Ammar Mallouhi , Michael Rieger , Benedikt Czermak , Martin C. Freund , Peter Waldenberger

DOI: 10.2214/AJR.180.1.1800233

关键词:

摘要: OBJECTIVE. The purpose of our study was to evaluate the role multidetector CT (MDCT) angiography with volume rendering for estimating patency renal artery stents.SUBJECTS AND METHODS. In 16 patients, stents were evaluated MDCT and digital subtraction (DSA). data using multiplanar reformations volume-rendering algorithm three different volume-rendered parameter settings (low-to-high, high-to-low, high—low—high opacity transfer functions: VRLH, VRHL, VRVE, respectively). Targeted images each stent rendered in paraaxial paracoronal planes interactively interpreted. overall restenosis severity measured on postprocessed compared that obtained DSA linear regression analysis. Image quality lumen delineation also Wilcoxon's signed rank test.RESULTS. Eight restenoses identified DS...

参考文章(20)
Geoffrey D. Rubin, Maria C. Shiau, Ann N. Leung, Stephen T. Kee, Laura J. Logan, Mark C. Sofilos, Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography Radiology. ,vol. 215, pp. 670- 676 ,(2000) , 10.1148/RADIOLOGY.215.3.R00JN18670
Kimberly A. Addis, Kenneth D. Hopper, Tunç A. Iyriboz, Yi Liu, Scott W. Wise, Claudia J. Kasales, Judy S. Blebea, David T. Mauger, CT Angiography American Journal of Roentgenology. ,vol. 177, pp. 1171- 1176 ,(2001) , 10.2214/AJR.177.5.1771171
X. Leclerc, J. Y. Gauvrit, J. P. Pruvo, Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting. American Journal of Roentgenology. ,vol. 174, pp. 820- 822 ,(2000) , 10.2214/AJR.174.3.1740820
M Galanski, M Prokop, A Chavan, C M Schaefer, K Jandeleit, J E Nischelsky, Renal arterial stenoses: spiral CT angiography. Radiology. ,vol. 189, pp. 185- 192 ,(1993) , 10.1148/RADIOLOGY.189.1.8372191
Paul R. Hilfiker, Harald H. Quick, Jörg F. Debatin, Plain and covered stent-grafts: in vitro evaluation of characteristics at three-dimensional MR angiography. Radiology. ,vol. 211, pp. 693- 697 ,(1999) , 10.1148/RADIOLOGY.211.3.R99JN23693
J. Martin Bland, DouglasG. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet. ,vol. 327, pp. 307- 310 ,(1986) , 10.1016/S0140-6736(86)90837-8
H. SVANHOLM, H. STARKLINT, H. J. G. GUNDERSEN, J. FABRICIUS, H. BARLEBO, S. OLSEN, Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic Apmis. ,vol. 97, pp. 689- 698 ,(1989) , 10.1111/J.1699-0463.1989.TB00464.X
B S Kuszyk, D G Heath, P T Johnson, J Eng, E K Fishman, CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy. American Journal of Roentgenology. ,vol. 173, pp. 449- 455 ,(1999) , 10.2214/AJR.173.2.10430152
Jeffrey V. Behar, Rendon C. Nelson, James P. Zidar, David M. DeLong, Tony P. Smith, Thin-section multidetector CT angiography of renal artery stents. American Journal of Roentgenology. ,vol. 178, pp. 1155- 1159 ,(2002) , 10.2214/AJR.178.5.1781155
Jeannette Bakker, Jaap J. Beutler, Otto E. H. Elgersma, Eduard E. de Lange, Gérard A. P. de Kort, Frederik J. A. Beek, Duplex ultrasonography in assessing restenosis of renal artery stents. CardioVascular and Interventional Radiology. ,vol. 22, pp. 475- 480 ,(1999) , 10.1007/S002709900435