Assessment of the Anterior Chamber Angle in Patients with Nanophthalmos: An Anterior Segment Optical Coherence Tomography Study

作者: Necip Kara , Okkes Baz , Hasan Altinkaynak , Cigdem Altan , Ahmet Demirok

DOI: 10.3109/02713683.2013.774025

关键词:

摘要: ABSTRACTPurpose: To quantitatively assess the parameters of anterior chamber and angle dimensions by segment optical coherence tomography (AS-OCT) in nanophthalmos.Methods: In this prospective, cross-sectional comparative study, 34 eyes healthy individuals (control group) 37 patients with nanophthalmos (study were enrolled. A single experienced ophthalmologist imaged measured right eye Visante AS-OCT. The (ACA), opening distance (AOD) at 500 750 µm from scleral spur, trabecular–iris space area (TISA) nasal temporal angles measured.Results: Mean nasal/temporal ACA was 44.90 ± 9.09/47.07 ± 8.69° control group 32.15 ± 10.30/29.77 ± 10.57° study (p < 0.001). AOD500 AOD750 0.52 ± 0.18/0.53 ± 0.15 mm 0.71 ± 0.26/0.71 ± 0.23 mm group. mean 0.33 ± 0.12/0.31 ± 0.15 mm ...

参考文章(31)
Laurence S Lim, Tin Aung, Rahat Husain, Ying-Juan Wu, Gus Gazzard, Steve K.L Seah, Acute primary angle closure: Configuration of the drainage angle in the first year after laser peripheral iridotomy Ophthalmology. ,vol. 111, pp. 1470- 1474 ,(2004) , 10.1016/J.OPHTHA.2004.01.036
Edward A. Ryan, Johan Zwaan, Leo T. Chylack, Nanophthalmos with Uveal Effusion: Clinical and Embryologic Considerations Ophthalmology. ,vol. 89, pp. 1013- 1017 ,(1982) , 10.1016/S0161-6420(82)34686-2
David P. Piñero, Ana Belén Plaza, Jorge L. Alió, Anterior segment biometry with 2 imaging technologies: very-high-frequency ultrasound scanning versus optical coherence tomography. Journal of Cataract and Refractive Surgery. ,vol. 34, pp. 95- 102 ,(2008) , 10.1016/J.JCRS.2007.08.033
Jae Hong Sun, Kyung Rim Sung, Sung-Cheol Yun, Mi Hyun Cheon, Hung Won Tchah, Myoung Joon Kim, Jae Yong Kim, Factors associated with anterior chamber narrowing with age: an optical coherence tomography study. Investigative Ophthalmology & Visual Science. ,vol. 53, pp. 2607- 2610 ,(2012) , 10.1167/IOVS.11-9359
Ningli Wang, Bingsong Wang, Gaoshou Zhai, Kun Lei, Lan Wang, Nathan Congdon, A Method of Measuring Anterior Chamber Volume Using the Anterior Segment Optical Coherence Tomographer and Specialized Software American Journal of Ophthalmology. ,vol. 143, pp. 879- 881 ,(2007) , 10.1016/J.AJO.2006.11.051
Joseph A Izatt, Michael R Hee, Eric A Swanson, Charles P Lin, David Huang, Joel S Schuman, Carmen A Puliafito, James G Fujimoto, Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography Archives of Ophthalmology. ,vol. 112, pp. 1584- 1589 ,(1994) , 10.1001/ARCHOPHT.1994.01090240090031
Claude Burgoyne, Nanophthalmia and chronic angle-closure glaucoma. Journal of Glaucoma. ,vol. 11, pp. 525- 528 ,(2002) , 10.1097/00061198-200212000-00013
Nishani Amerasinghe, Paul J. Foster, Tien Yin Wong, Hla Myint Htoon, Mingguang He, Sunny Y. Shen, Han T. Aung, Seang-Mei Saw, Tin Aung, Variation of angle parameters in asians: an anterior segment optical coherence tomography study in a population of singapore malays. Investigative Ophthalmology & Visual Science. ,vol. 50, pp. 2626- 2631 ,(2009) , 10.1167/IOVS.08-2582
H. Hoerauf, C. Wirbelauer, C. Scholz, R. Engelhardt, P. Koch, H. Laqua, R. Birngruber, Slit-lamp-adapted optical coherence tomography of the anterior segment. Graefes Archive for Clinical and Experimental Ophthalmology. ,vol. 238, pp. 8- 18 ,(2000) , 10.1007/S004170050002