Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol.

作者: George S. Stergiou , Dimitris Tzamouranis , Athanasios Protogerou , Efthimia Nasothimiou , Christos Kapralos

DOI: 10.1097/MBP.0B013E3283057AF6

关键词:

摘要: ObjectiveTo assess the accuracy of oscillometric and auscultatory blood pressure (BP) measurement taken using professional electronic device Microlife Watch BP Office according to European Society Hypertension International Protocol.MethodsThirty-three participants were included for a

参考文章(9)
William Gerin, Rose Merie Marion, Richard Friedman, Gary D. James, Dana H. Bovbjerg, Thomas G. Pickering, How should we measure blood pressure in the doctor's office? Blood Pressure Monitoring. ,vol. 6, pp. 257- 262 ,(2001) , 10.1097/00126097-200110000-00006
Thomas G. Pickering, Should doctors still measure blood pressure Journal of Clinical Hypertension. ,vol. 8, pp. 394- 396 ,(2006) , 10.1111/J.1524-6175.2006.05154.X
G STERGIOU, How to cope with unreliable office blood pressure measurement American Journal of Hypertension. ,vol. 18, pp. 1519- 1521 ,(2005) , 10.1016/J.AMJHYPER.2005.07.014
Eoin O'Brien, Thomas Pickering, Roland Asmar, Martin Myers, Gianfranco Parati, Jan Staessen, Thomas Mengden, Yutaka Imai, Bernard Waeber, Paolo Palatini, William Gerin, None, Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults Blood Pressure Monitoring. ,vol. 7, pp. 3- 17 ,(2002) , 10.1097/00126097-200202000-00002
Eoin O'brien, Roland Asmar, Lawrie Beilin, Yutaka Imai, Jean-Michel Mallion, Giuseppe Mancia, Thomas Mengden, Martin Myers, Paul Padfield, Paolo Palatini, Gianfranco Parati, Thomas Pickering, Josep Redon, Jan Staessen, George Stergiou, Paolo Verdecchia, European Society of Hypertension Working Group on Blood Pressure Monitoring, None, European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. Journal of Hypertension. ,vol. 21, pp. 821- 848 ,(2003) , 10.1097/00004872-200305000-00001
M. G. Myers, N. H. McInnis, G. J. Fodor, F. H. H. Leenen, Comparison between an automated and manual sphygmomanometer in a population survey. American Journal of Hypertension. ,vol. 21, pp. 280- 283 ,(2008) , 10.1038/AJH.2007.54
G. S. Stergiou, Office blood pressure measurement with electronic devices: has the time come? American Journal of Hypertension. ,vol. 21, pp. 246- 246 ,(2008) , 10.1038/AJH.2007.78
Thomas G. Pickering, What will replace the mercury sphygmomanometer Blood Pressure Monitoring. ,vol. 8, pp. 23- 25 ,(2003) , 10.1097/00126097-200302000-00005