Use of a digitally reconstructed radiograph-based computer simulation for the optimisation of chest radiographic techniques for computed radiography imaging systems

作者: C S Moore , G Avery , S Balcam , L Needler , A Swift

DOI: 10.1259/BJR/47377285

关键词:

摘要: Objectives The purpose of this study was to derive an optimum radiographic technique for computed radiography (CR) chest imaging using a digitally reconstructed radiograph computer simulator. simulator is capable producing CR radiographs adults with various tube potentials, receptor doses and scatter rejection. Methods Four experienced image evaluators graded images average obese adult patients at different potentials (average-sized, n=50; obese, n=20), (n=10) rejection techniques n=20; n=20). quality the evaluated visually analysis. influence rib contrast also assessed. Results For average-sized patients, improved when potential reduced compared reference (102 kVp). No indicated. it has been shown that antiscatter grid indicated, should be used in conjunction as low possible (while al...

参考文章(44)
Markus Håkansson, Magnus Båth, Sara Börjesson, Susanne Kheddache, Anna Grahn, Mark Ruschin, Anders Tingberg, Sören Mattsson, Lars Gunnar Månsson, Nodule detection in digital chest radiography: Summary of the radius chest trial Radiation Protection Dosimetry. ,vol. 114, pp. 114- 120 ,(2005) , 10.1093/RPD/NCH574
Lee Westover, Interactive volume rendering Proceedings of the 1989 Chapel Hill workshop on Volume visualization. pp. 9- 16 ,(1989) , 10.1145/329129.329138
N Milickovic, D Baltas, S Giannouli, M Lahanas, N Zamboglou, CT imaging based digitally reconstructed radiographs and their application in brachytherapy. Physics in Medicine and Biology. ,vol. 45, pp. 2787- 2800 ,(2000) , 10.1088/0031-9155/45/10/305
Anders Tingberg, David Sjöström, Optimisation of image plate radiography with respect to tube voltage. Radiation Protection Dosimetry. ,vol. 114, pp. 286- 293 ,(2005) , 10.1093/RPD/NCH536
Susanne Kheddache, Lars Gunnar M�nsson, Patrik Sund, Magnus B�th, Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography. European Radiology. ,vol. 14, pp. 48- 58 ,(2004) , 10.1007/S00330-003-1971-Z
Michael Sandborg, Anders Tingberg, Gustaf Ullman, David R. Dance, Gudrun Alm Carlsson, Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages Medical Physics. ,vol. 33, pp. 4169- 4175 ,(2006) , 10.1118/1.2362871
NOBUHIRO ODA, HAJIME NAKATA, SEIICHI MURAKAMI, KUNIHIRO TERADA, KATSUMI NAKAMURA, AKIRA YOSHIDA, Optimal beam quality for chest computed radiography. Investigative Radiology. ,vol. 31, pp. 126- 131 ,(1996) , 10.1097/00004424-199603000-00002
P C Shrimpton, B F Wall, E S Fisher, The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities. Physics in Medicine and Biology. ,vol. 26, pp. 133- 139 ,(1981) , 10.1088/0031-9155/26/1/013
Magnus Båth, Markus Håkansson, Sara Börjesson, Susanne Kheddache, Anna Grahn, François O. Bochud, Francis R. Verdun, Lars Gunnar Månsson, Nodule detection in digital chest radiography: part of image background acting as pure noise. Radiation Protection Dosimetry. ,vol. 114, pp. 102- 108 ,(2005) , 10.1093/RPD/NCH523