Validation of MET estimates and step measurement using the ActivPAL physical activity logger

作者: Deirdre M Harrington , Gregory J Welk , Alan E Donnelly , None

DOI: 10.1080/02640414.2010.549499

关键词:

摘要: Abstract The purpose of this study was to determine the validity metabolic equivalent (MET) equation and step rate function ActivPAL™ physical activity logger in a group females. Using standard treadmill protocol, 62 females aged 15–25 years walked on at speeds between 3.2 7.0 km · h−1 while wearing an ActivPAL. Oxygen consumption measured using expired gas analysis each speed METs for were estimated based participant's own resting rate. A sub-set 18 participants also wore Actigraph. Results showed that in-built ActivPAL significantly underestimated (P   0.05) video...

参考文章(32)
Edward M Winter, None, JUMPING: POWER OR IMPULSE? Medicine and Science in Sports and Exercise. ,vol. 37, pp. 523- 524 ,(2005) , 10.1249/01.MSS.0000155703.50713.26
STEWART G. TROST, REBECCA WAY, ANTHONY D. OKELY, Predictive validity of three ActiGraph energy expenditure equations for children Medicine and Science in Sports and Exercise. ,vol. 38, pp. 380- 387 ,(2006) , 10.1249/01.MSS.0000183848.25845.E0
Miguel A Calabro, Gregory J Welk, Joey C Eisenmann, None, Validation of the SenseWear Pro Armband algorithms in children. Medicine and Science in Sports and Exercise. ,vol. 41, pp. 1714- 1720 ,(2009) , 10.1249/MSS.0B013E3181A071CF
PATTY FREEDSON, DAVID POBER, KATHLEEN F. JANZ, Calibration of accelerometer output for children. Medicine and Science in Sports and Exercise. ,vol. 37, ,(2005) , 10.1249/01.MSS.0000185658.28284.BA
K F Janz, Physical activity in epidemiology: moving from questionnaire to objective measurement British Journal of Sports Medicine. ,vol. 40, pp. 191- 192 ,(2006) , 10.1136/BJSM.2005.023036
PATTY S. FREEDSON, EDWARD MELANSON, JOHN SIRARD, Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise. ,vol. 30, pp. 777- 781 ,(1998) , 10.1097/00005768-199805000-00021
GUY C. LE MASURIER, CATRINE TUDOR-LOCKE, Comparison of pedometer and accelerometer accuracy under controlled conditions. Medicine and Science in Sports and Exercise. ,vol. 35, pp. 867- 871 ,(2003) , 10.1249/01.MSS.0000064996.63632.10
Stewart G. Trost, State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents American Journal of Lifestyle Medicine. ,vol. 1, pp. 299- 314 ,(2007) , 10.1177/1559827607301686
GUY C. LE MASURIER, SARAH M. LEE, CATRINE TUDOR-LOCKE, Motion sensor accuracy under controlled and free-living conditions. Medicine and Science in Sports and Exercise. ,vol. 36, pp. 905- 910 ,(2004) , 10.1249/01.MSS.0000126777.50188.73