Brief effect of acupuncture on the peripheral arterial system of the upper limb and systemic hemodynamics in humans.

作者: Shin Takayama , Takashi Seki , Masashi Watanabe , Yasutake Monma , San Yue Yang

DOI: 10.1089/ACM.2009.0355

关键词:

摘要: Abstract Background: Pulse diagnosis of the peripheral artery is an important technique in Traditional Chinese Medicine, where, acupuncture therapy, treatment adjusted according to observed changes pulse. We investigated change blood flow and cardiac index during treatment. Objectives: The aim this study explore effect on radial brachial volume healthy subjects. Methods: Eighteen (18) volunteers were enrolled. Acupuncture was performed bilaterally LR-3 with manual rotation needles. pressure heart rate measured at rest 180 seconds after acupuncture. Radial monitored continuously by ultrasound echo-tracking system. Cardiac impedance cardiography. hemodynamic parameters before, during, 30, 60, Results...

参考文章(31)
Madden Jl, Castillo Ht, Lee By, Quantification of the arterial pulsatile blood flow waveform in peripheral vascular disease. Angiology. ,vol. 21, pp. 595- 605 ,(1970)
Junko Soga, Kenji Nishioka, Shuji Nakamura, Takashi Umemura, Daisuke Jitsuiki, Takayuki Hidaka, Hiroki Teragawa, Hiroaki Takemoto, Chikara Goto, Masao Yoshizumi, Kazuaki Chayama, Yukihito Higashi, Measurement of flow-mediated vasodilation of the brachial artery: a comparison of measurements in the seated and supine positions. Japanese Circulation Journal-english Edition. ,vol. 71, pp. 736- 740 ,(2007) , 10.1253/CIRCJ.71.736
Shepherd Jt, Roddie Ic, Whelan Rf, The vasomotor nerve supply to the skin and muscle of the human forearm. Clinical Science. ,vol. 16, pp. 67- 74 ,(1957)
Mary C Corretti, Todd J Anderson, Emelia J Benjamin, David Celermajer, Francois Charbonneau, Mark A Creager, John Deanfield, Helmut Drexler, Marie Gerhard-Herman, David Herrington, Patrick Vallance, Joseph Vita, Robert Vogel, Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: A report of the International Brachial Artery Reactivity Task Force Journal of the American College of Cardiology. ,vol. 39, pp. 257- 265 ,(2002) , 10.1016/S0735-1097(01)01746-6
Nancy M. Albert, Melanie D. Hail, Jianbo Li, James B. Young, Equivalence of the Bioimpedance and Thermodilution Methods in Measuring Cardiac Output in Hospitalized Patients With Advanced, Decompensated Chronic Heart Failure American Journal of Critical Care. ,vol. 13, pp. 469- 479 ,(2004) , 10.4037/AJCC2004.13.6.469
Charles L Springfield, Frank Sebat, David Johnson, Steven Lengle, Christian Sebat, None, Utility of Impedance Cardiography to Determine Cardiac vs. Noncardiac Cause of Dyspnea in the Emergency Department Congestive Heart Failure. ,vol. 10, pp. 14- 16 ,(2004) , 10.1111/J.1527-5299.2004.03409.X
Albert C. Perrino, Amy Lippman, Christopher Ariyan, Teresa Z. O'Connor, Martha Luther, Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution. Journal of Cardiothoracic and Vascular Anesthesia. ,vol. 8, pp. 24- 29 ,(1994) , 10.1016/1053-0770(94)90007-8
Robert W. Gill, Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound in Medicine and Biology. ,vol. 11, pp. 625- 641 ,(1985) , 10.1016/0301-5629(85)90035-3
R Guo, The Foundations of Chinese Medicine Focus on Alternative and Complementary Therapies. ,vol. 11, pp. 71- 71 ,(2010) , 10.1111/J.2042-7166.2006.TB01251.X