Quantitative analysis of different volatile organic compounds using an improved electronic nose

作者: Daqi Gao , Jiuming Ji , Jiayu Gong , Chaoqian Cai

DOI: 10.1088/0957-0233/23/10/105103

关键词:

摘要: This paper sets up an improved electronic nose with automatic sampling mode, large volumetric vapors and constant temperature for headspace gas sensor array. In order to facilitate the fast recovery good repeatability of sensors, steps taken include (A) short-time contact odors measured; (B) long-time purification using environmental air; (C) exact calibration clean air before sampling. We employ multiple single-output perceptrons discriminate quantify kinds odors. task is first regarded as two-class discrimination problems then quantification problems, accomplished by followed perceptrons. The experimental results measuring quantifying 12 volatile organic compounds changing concentrations show that type a hierarchical perceptron model has simple structure, easy operation, performance.

参考文章(20)
Jorge Orts, Eduard Llobet, Xavier Vilanova, Jesus Brezmes, Xavier Correig, Selective methane detection under varying moisture conditions using static and dynamic sensor signals Sensors and Actuators B-chemical. ,vol. 60, pp. 106- 117 ,(1999) , 10.1016/S0925-4005(99)00257-9
Dae-Sik Lee, Jong-Kyong Jung, Jun-Woo Lim, Jeung-Soo Huh, Duk-Dong Lee, Recognition of volatile organic compounds using SnO2 sensor array and pattern recognition analysis Sensors and Actuators B-chemical. ,vol. 77, pp. 228- 236 ,(2001) , 10.1016/S0925-4005(01)00718-3
Nabarun Bhattacharya, Bipan Tudu, Arun Jana, Devdulal Ghosh, Rajib Bandhopadhyaya, Amiya Baran Saha, Illumination heating and physical raking for increasing sensitivity of electronic nose measurements with black tea Sensors and Actuators B-chemical. ,vol. 131, pp. 37- 42 ,(2008) , 10.1016/J.SNB.2007.12.031
J RAGAZZOSANCHEZ, P CHALIER, D CHEVALIER, M CALDERONSANTOYO, C GHOMMIDH, Identification of different alcoholic beverages by electronic nose coupled to GC Sensors and Actuators B-chemical. ,vol. 134, pp. 43- 48 ,(2008) , 10.1016/J.SNB.2008.04.006
A Szczurek, P.M Szecówka, B.W Licznerski, Application of sensor array and neural networks for quantification of organic solvent vapours in air Sensors and Actuators B: Chemical. ,vol. 58, pp. 427- 432 ,(1999) , 10.1016/S0925-4005(99)00105-7
Patrick Mielle, Florence Marquis, Gas Sensors Arrays (‘Electronic Noses’): a study about the speed/accuracy ratio Sensors and Actuators B-chemical. ,vol. 68, pp. 9- 16 ,(2000) , 10.1016/S0925-4005(00)00440-8
K. Brudzewski, S. Osowski, K. Wolinska, J. Ulaczyk, Smell similarity on the basis of gas sensor array measurements Sensors and Actuators B-chemical. ,vol. 129, pp. 643- 651 ,(2008) , 10.1016/J.SNB.2007.09.050
Eduard Llobet, Jesús Brezmes, Xavier Vilanova, Jesús E. Sueiras, Xavier Correig, Qualitative and quantitative analysis of volatile organic compounds using transient and steady-state responses of a thick-film tin oxide gas sensor array Sensors and Actuators B-chemical. ,vol. 41, pp. 13- 21 ,(1997) , 10.1016/S0925-4005(97)80272-9
G. Horner, Chr. Hierold, Gas analysis by partial model building Sensors and Actuators B: Chemical. ,vol. 2, pp. 173- 184 ,(1990) , 10.1016/0925-4005(90)85002-G
V.Yu. Musatov, V.V. Sysoev, M. Sommer, I. Kiselev, Assessment of meat freshness with metal oxide sensor microarray electronic nose: A practical approach Sensors and Actuators B-chemical. ,vol. 144, pp. 99- 103 ,(2010) , 10.1016/J.SNB.2009.10.040