作者: Ammar Necaibia , Ahmed Bouraiou , Abderrezzaq Ziane , Nordine Sahouane , Samir Hassani
DOI: 10.1016/J.ENCONMAN.2018.06.020
关键词:
摘要: Abstract A detailed assessment analysis of 2.5 kWp photovoltaic (PV) system located in southern Algeria (Latitude 27.88 °N, Longitude −0.27 °E, Altitude 262 m) has been carried out this paper order to support the growth grid-tied power plant implementation Saharan environment. The achievement done by performing an accurate evaluation different impacts environment parameters on operating performance PV system. data set covers 12 months and collected our team from Research Unit Renewable Energy (URER-MS). experimental reveal that environmental variation direct effect both energy conversion efficiency losses. grid was supplied with a 4322.65 kWh during year 2015, where annual average temperature 28.30 °C. An important have observed for months. yield values max/min monthly daily reference, array final were; 7.68/5.7 kW h/kWp/day, 6.07/4.24 kW h/kWp/day 5.75/3.98 kW h/kWp/day, respectively. module, inverter overall reached; 14.19/11.10%, 95.34/93.94% 13.53/10.50%, results indicate ratio (PR) varies 66.66% 85.93% capacity factor 7.91%.