Inter- and Intraobserver Reliability of Two-dimensional CT Scan for Total Knee Arthroplasty Component Malrotation

作者: Beau Konigsberg , Ryan Hess , Curtis Hartman , Lynette Smith , Kevin L Garvin

DOI: 10.1007/S11999-013-3111-7

关键词:

摘要: Background Rotational malalignment of total knee arthroplasty (TKA) has been correlated with patellofemoral maltracking, instability, and stiffness. CT is the most accurate method to assess rotational alignment prosthetic components after TKA, but inter- intraobserver reliability scans for this use not well documented.

参考文章(22)
Roger Torga-Spak, Shital Parikh, Steven Stuchin, Anterior knee pain due to biplanar rotatory malalignment of the femoral component in total knee arthroplasty. Case report. Journal of Knee Surgery. ,vol. 17, pp. 113- 116 ,(2010) , 10.1055/S-0030-1248207
Ryuji Nagamine, Stephen E. White, Daniel S. McCarthy, Leo A. Whiteside, Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty Journal of Arthroplasty. ,vol. 10, pp. 265- 270 ,(1995) , 10.1016/S0883-5403(05)80172-X
R. A. Berger, L. S. Crossett, J. J. Jacobs, H. E. Rubash, Malrotation causing patellofemoral complications after total knee arthroplasty. Clinical Orthopaedics and Related Research. ,vol. 356, pp. 144- 153 ,(1998) , 10.1097/00003086-199811000-00021
Kouichi Kanekasu, Makoto Kondo, Yoshinori Kadoya, Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty Clinical Orthopaedics and Related Research. ,vol. 434, pp. 193- 197 ,(2005) , 10.1097/01.BLO.0000156819.24866.8B
J. Martin Bland, Douglas G. Altman, Statistical methods for assessing agreement between two methods of clinical measurement International Journal of Nursing Studies. ,vol. 47, pp. 931- 936 ,(2010) , 10.1016/J.IJNURSTU.2009.10.001
Laith M. Jazrawi, Luther Birdzell, Frederick J. Kummer, Paul E. Di Cesare, The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation Journal of Arthroplasty. ,vol. 15, pp. 761- 766 ,(2000) , 10.1054/ARTH.2000.8193
Stephen J Incavo, John J Wild, Kathryn M Coughlin, Bruce D Beynnon, Early revision for component malrotation in total knee arthroplasty. Clinical Orthopaedics and Related Research. ,vol. 458, pp. 131- 136 ,(2007) , 10.1097/BLO.0B013E3180332D97
J. Martin Bland, DouglasG. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet. ,vol. 327, pp. 307- 310 ,(1986) , 10.1016/S0140-6736(86)90837-8
RICHARD A. BERGER, HARRY E. RUBASH, MICHAEL J. SEEL, WARREN H. THOMPSON, LAWRENCE S. CROSSETT, Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clinical Orthopaedics and Related Research. ,vol. 286, pp. 40- 47 ,(1993) , 10.1097/00003086-199301000-00008
Richard A. Berger, Harry E. Rubash, Rotational instability and malrotation after total knee arthroplasty. Orthopedic Clinics of North America. ,vol. 32, pp. 639- 647 ,(2001) , 10.1016/S0030-5898(05)70233-9