作者: D. Bruce Montgomery
DOI: 10.1063/1.1753698
关键词:
摘要: Explanation of the discrepancy between Nb -- Zr short sample tests and solenoid performance prediction current carrying capacity solenoids are based on mechanism induced persistent-eddy currents. Study residual fields following reduction magnetic field strength to zero leads assumptions permitting calculations circulating magnitudes. Data presented graphically, generation same using less material is found result from spreading out layers or turns. (D.C.W.)