MR imaging of knee hyaline cartilage: Evaluation of two- and three-dimensional sequences

作者: Osmo Tervonen , Mark J. Dietz , Stephen W. Carmichael , Richard L. Ehman

DOI: 10.1002/JMRI.1880030417

关键词:

摘要: Magnetic resonance (MR) imaging of cadaveric knees was performed to determine optimal sequences for visualization hyaline cartilage. Full-thickness cartilage lesions ranging in diameter from 1 5 mm and a partial-thickness lesion 15 were created the femoral articular surfaces three knees. The then imaged with 1.5-T imager various two-dimensional high-resolution three-dimensional (3D) techniques. After imaging, knee specimens sectioned evaluation. Measurements thickness fast spin-echo images correlated best those gross specimen. Diffuse areas thinning also most accurately identified images. Small, focal defects delineated 3D SPGR (spoiled GRASS [gradient-recalled acquisition steady state])

参考文章(15)
VM Gylys-Morin, PC Hajek, DJ Sartoris, D Resnick, Articular cartilage defects: detectability in cadaver knees with MR American Journal of Roentgenology. ,vol. 148, pp. 1153- 1157 ,(1987) , 10.2214/AJR.148.6.1153
B S Yulish, J M Lieberman, S E Strandjord, P J Bryan, G P Mulopulos, M T Modic, Hemophilic arthropathy: assessment with MR imaging. Radiology. ,vol. 164, pp. 759- 762 ,(1987) , 10.1148/RADIOLOGY.164.3.3615876
J Beltran, J L Caudill, L A Herman, S M Kantor, P N Hudson, A M Noto, A S Baran, Rheumatoid arthritis: MR imaging manifestations. Radiology. ,vol. 165, pp. 153- 157 ,(1987) , 10.1148/RADIOLOGY.165.1.3628762
H König, R Sauter, M Deimling, M Vogt, Cartilage disorders: comparison of spin-echo, CHESS, and FLASH sequence MR images. Radiology. ,vol. 164, pp. 753- 758 ,(1987) , 10.1148/RADIOLOGY.164.3.3615875
AT Watanabe, BC Carter, GP Teitelbaum, LL Seeger, WG Bradley Jr, None, Normal variations in MR imaging of the knee: appearance and frequency American Journal of Roentgenology. ,vol. 153, pp. 341- 344 ,(1989) , 10.2214/AJR.153.2.341
Deutsch Al, Mink Jh, Magnetic resonance imaging of musculoskeletal injuries. Radiologic Clinics of North America. ,vol. 27, pp. 983- 1002 ,(1989)
J M Modl, L A Sether, V M Haughton, J B Kneeland, Articular cartilage: correlation of histologic zones with signal intensity at MR imaging. Radiology. ,vol. 181, pp. 853- 855 ,(1991) , 10.1148/RADIOLOGY.181.3.1947110
Anna E. Holsinger, Stephen J. Riederer, The importance of phase-encoding order in ultra-short TR snapshot MR imaging. Magnetic Resonance in Medicine. ,vol. 16, pp. 481- 488 ,(1990) , 10.1002/MRM.1910160315