Enzyme-free hydrogen peroxide sensor based on Au@Ag@C core-double shell nanocomposites

作者: Yancai Li , Yayun Zhang , Yanmei Zhong , Shunxing Li

DOI: 10.1016/J.APSUSC.2015.04.102

关键词:

摘要: Abstract The well-designed Au@Ag@C core-double shell nanocomposites were synthesized via a facile method, and used to fabricate an enzyme-free amperometric hydrogen peroxide (H 2 O ) sensor. size, shape, elementary composition structure of the characterized by transmission electron microscope (TEM), energy-dispersed spectrum (EDS) X-ray diffraction (XRD). outermost layer was amorphous carbon, second Ag core Au. exhibit attractive activity for electrocatalytic reduction H according electrochemical experiments. It also demonstrates sensor possess well performance with wide linear range 5.0 μM 4.75 mM limit detection (LOD) as low 0.14 μM ( S / N  = 3). Furthermore, interference from common interfering species, such glucose, ascorbic acid, dopamine uric acid can be effectively avoided. In word, are promising candidates

参考文章(46)
S.R. Parks, J.T. Walker, A.M. Bennett, K. Bentley, B.K. Dove, Hydrogen peroxide vapour decontamination of surfaces artificially contaminated with norovirus surrogate feline calicivirus Journal of Hospital Infection. ,vol. 80, pp. 116- 121 ,(2012) , 10.1016/J.JHIN.2011.10.010
Wenhui Yuan, Yejian Gu, Li Li, Green synthesis of graphene/Ag nanocomposites Applied Surface Science. ,vol. 261, pp. 753- 758 ,(2012) , 10.1016/J.APSUSC.2012.08.094
G Laruelle, J Parvole, J Francois, L Billon, Block copolymer grafted-silica particles: a core/double shell hybrid inorganic/organic material Polymer. ,vol. 45, pp. 5013- 5020 ,(2004) , 10.1016/J.POLYMER.2004.05.030
Joaquim C.G. Esteves da Silva, Helena M.R. Gonçalves, Analytical and bioanalytical applications of carbon dots Trends in Analytical Chemistry. ,vol. 30, pp. 1327- 1336 ,(2011) , 10.1016/J.TRAC.2011.04.009
Kuan-Jung Chen, K. Chandrasekara Pillai, John Rick, Chun-Jern Pan, Shih-Han Wang, Chung-Chiun Liu, Bing-Joe Hwang, Bimetallic PtM (M = Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H2O2 Biosensors and Bioelectronics. ,vol. 33, pp. 120- 127 ,(2012) , 10.1016/J.BIOS.2011.12.037
Kathy K. Griendling, Garret A. FitzGerald, Oxidative Stress and Cardiovascular Injury Part I: Basic Mechanisms and In Vivo Monitoring of ROS Circulation. ,vol. 108, pp. 1912- 1916 ,(2003) , 10.1161/01.CIR.0000093660.86242.BB
Ye Li, Jing-Jing Zhang, Jie Xuan, Li-Ping Jiang, Jun-Jie Zhu, Fabrication of a novel nonenzymatic hydrogen peroxide sensor based on Se/Pt nanocomposites Electrochemistry Communications. ,vol. 12, pp. 777- 780 ,(2010) , 10.1016/J.ELECOM.2010.03.031