Validation of a spatially variant resolution model for small animal brain PET studies

作者: Alan Miranda , Daniele Bertoglio , Dorien Glorie , Sigrid Stroobants , Steven Staelens

DOI: 10.1088/2057-1976/AB8C13

关键词:

摘要: … , [ 18 F]FDG mice brain scans of mice … mouse brain PET scans, quantification in small brain regions is challenging. Using the spatially variant resolution model implemented here, brain …

参考文章(17)
Long Zhang, Steven Staelens, Roel Van Holen, Jan De Beenhouwer, Jeroen Verhaeghe, Iwan Kawrakow, Stefaan Vandenberghe, Fast and memory‐efficient Monte Carlo‐based image reconstruction for whole‐body PET Medical Physics. ,vol. 37, pp. 3667- 3676 ,(2010) , 10.1118/1.3455287
Nicolas Aide, Cédric Desmonts, Jean-Mathieu Beauregard, Thomas Beyer, Kathryn Kinross, Peter Roselt, Oliver Neels, Denis Agostini, Stéphane Bardet, Gérard Bouvard, Rodney J. Hicks, High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 37, pp. 991- 1001 ,(2010) , 10.1007/S00259-009-1352-1
Steven Deleye, Roel Van Holen, Jeroen Verhaeghe, Stefaan Vandenberghe, Sigrid Stroobants, Steven Staelens, Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging. European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 40, pp. 744- 758 ,(2013) , 10.1007/S00259-012-2326-2
Kisung Lee, Paul E Kinahan, Jeffrey A Fessler, Robert S Miyaoka, Marie Janes, Tom K Lewellen, Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner Physics in Medicine and Biology. ,vol. 49, pp. 4563- 4578 ,(2004) , 10.1088/0031-9155/49/19/008
E Rapisarda, V Bettinardi, K Thielemans, M C Gilardi, Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET. Physics in Medicine and Biology. ,vol. 55, pp. 4131- 4151 ,(2010) , 10.1088/0031-9155/55/14/012
Arman Rahmim, Jinyi Qi, Vesna Sossi, Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls Medical Physics. ,vol. 40, pp. 064301- 064301 ,(2013) , 10.1118/1.4800806
C Cloquet, F C Sureau, M Defrise, G Van Simaeys, N Trotta, S Goldman, Non-Gaussian space-variant resolution modelling for list-mode reconstruction. Physics in Medicine and Biology. ,vol. 55, pp. 5045- 5066 ,(2010) , 10.1088/0031-9155/55/17/011
F A Kotasidis, J C Matthews, G I Angelis, P J Noonan, A Jackson, P Price, W R Lionheart, A J Reader, Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners Physics in Medicine and Biology. ,vol. 56, pp. 2917- 2942 ,(2011) , 10.1088/0031-9155/56/10/003
Jinyi Qi, Richard M Leahy, Simon R Cherry, Arion Chatziioannou, Thomas H Farquhar, High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner Physics in Medicine and Biology. ,vol. 43, pp. 1001- 1013 ,(1998) , 10.1088/0031-9155/43/4/027
Q. Bao, D. Newport, M. Chen, D. B. Stout, A. F. Chatziioannou, Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards The Journal of Nuclear Medicine. ,vol. 50, pp. 401- 408 ,(2009) , 10.2967/JNUMED.108.056374