Fault ride-through capability of a DFIG in isolated grids employing DVR and supercapacitor energy storage

作者: Spyros I. Gkavanoudis , Charis S. Demoulias

DOI: 10.1016/J.IJEPES.2014.12.068

关键词:

摘要: Abstract In order to utilize Doubly Fed Induction Generators (DFIGs) as primary power source in an isolated system, they should be able regulate the voltage and frequency of system well ride-through faults. This paper proposes a new control strategy for DFIG operating accomplished by Dynamic Voltage Restorer (DVR) Supercapacitor Energy Storage System (SCESS), ride through symmetrical asymmetrical During faults, continues operate normally, while active mismatch is handled SCESS. particular, during DVR are properly controlled feed non-faulty phases uninterruptedly. When integrated with conventional synchronous generators, proposed improves Fault Ride-Through (FRT) capability DFIG, providing support throughout fault duration. Thus, transient stability significantly improved. The effectiveness method under different conditions verified detailed simulation results.

参考文章(27)
Jan Machowski, Zbigniew Lubosny, Janusz W Bialek, James R Bumby, Power System Dynamics: Stability and Control ,(2020)
Grzegorz Iwanski, Gonzalo Abad, Jesús López, Miguel A. Rodríguez, Luis Marroyo, Doubly Fed Induction Machine : Modeling and Control for Wind Energy Generation ,(2011)
Josep M. Guerrero, Jos Matas, Luis Garcia de Vicuna, Miguel Castilla, Jaume Miret, Decentralized Control for Parallel Operation of Distributed Generation Inverters Using Resistive Output Impedance IEEE Transactions on Industrial Electronics. ,vol. 54, pp. 994- 1004 ,(2007) , 10.1109/TIE.2007.892621
X. Tu, L.-A. Dessaint, M. El Kahel, A. Barry, Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics Mathematics and Computers in Simulation. ,vol. 71, pp. 425- 439 ,(2006) , 10.1016/J.MATCOM.2006.02.003
Rubén Pena, Roberto Cardenas, Enrique Escobar, Jon Clare, Pat Wheeler, Control strategy for a doubly-fed induction generator feeding an unbalanced grid or stand-alone load Electric Power Systems Research. ,vol. 79, pp. 355- 364 ,(2009) , 10.1016/J.EPSR.2008.07.005
S. Muller, M. Deicke, R.W. De Doncker, Doubly fed induction generator systems for wind turbines IEEE Industry Applications Magazine. ,vol. 8, pp. 26- 33 ,(2002) , 10.1109/2943.999610
R. Pena, J.C. Clare, G.M. Asher, A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine IEE Proceedings - Electric Power Applications. ,vol. 143, pp. 380- 387 ,(1996) , 10.1049/IP-EPA:19960454
Anca D. Hansen, Gabriele Michalke, Fault ride-through capability of DFIG wind turbines Renewable Energy. ,vol. 32, pp. 1594- 1610 ,(2007) , 10.1016/J.RENENE.2006.10.008
AHM Abdur Rahim, EP Nowicki, Supercapacitor energy storage system for fault ride-through of a DFIG wind generation system Energy Conversion and Management. ,vol. 59, pp. 96- 102 ,(2012) , 10.1016/J.ENCONMAN.2012.03.003