The effect of a tin barrier layer on the permeability of hydrogen through mild steel and ferritic stainless steel

作者: J. Bowker , G. R. Piercy

DOI: 10.1007/BF02646843

关键词:

摘要: Experiments were performed to measure the effectiveness of a commercially electroplated tin layer as barrier hydrogen, and see how this altered when was converted FeSn. The authors measured permeability hydrogen through AISI 410 ferritic stainless steel determined surface on it. values for in iron are shown.

参考文章(4)
D. R. Begeal, The permeation and diffusion of hydrogen and deuterium through Rodar, tin−coated Rodar, and solder−coated Rodar Journal of Vacuum Science and Technology. ,vol. 12, pp. 405- 409 ,(1975) , 10.1116/1.568586
S. S. Chatterjee, B. G. Ateya, H. W. Pickering, Effect of electrodeposited metals on the permeation of hydrogen through iron membranes Metallurgical and Materials Transactions A-physical Metallurgy and Materials Science. ,vol. 9, pp. 389- 395 ,(1978) , 10.1007/BF02646389
N.R Quick, H.H Johnson, Hydrogen and deuterium in iron, 49–506°C Acta Metallurgica. ,vol. 26, pp. 903- 907 ,(1978) , 10.1016/0001-6160(78)90041-X
A. J. Kumnick, H. H. Johnson, Steady state hydrogen transport through zone refined irons Metallurgical and Materials Transactions A-physical Metallurgy and Materials Science. ,vol. 6, pp. 1087- 1091 ,(1975) , 10.1007/BF02661363