Expert agreement in evaluating the optic disc for glaucoma.

作者: Rohit Varma , William C. Steinmann , Ingrid U. Scott

DOI: 10.1016/S0161-6420(92)31990-6

关键词:

摘要: The authors studied intraobserver and interobserver agreement, under monoscopic stereoscopic conditions, in estimating vertical cup-to-disc ratios assessing whether a disc had glaucomatous damage. Six glaucoma experts evaluated 75 optic photographs both viewing conditions. also re-evaluated 25 photographs. Intraobserver agreement cup-to was high (median weighted kappa, 0.79). Interobserver cup-todisc moderate (stereoscopic median 0.67); individual differed by as much 0.2 diameters (DD) monoscopically 0.16 DD stereoscopically. observers estimated larger when evaluating the same discs conditions than damage substantial 0.76). 0.50). This study confirms ability of to reliably evaluate within themselves emphasizes need for developing standardized methods evaluation glaucoma.

参考文章(18)
Roy M. Acheson, Yick-Kwong Chan, Margaret Payne, New Haven survey of joint diseases. The interrelationships between morning stiffness, nocturnal pain and swelling of the joints. Journal of Chronic Diseases. ,vol. 21, pp. 533- 542 ,(1969) , 10.1016/0021-9681(69)90049-6
Lichter Pr, Variability of expert observers in evaluating the optic disc. Transactions of the American Ophthalmological Society. ,vol. 74, pp. 532- 572 ,(1976)
Harold A. Kahn, Howard Leibowitz, James P. Ganley, Mohandas Kini, Theodore Colton, Rita Nickerson, Thomas R. Dawber, Standardizing Diagnostic Procedures American Journal of Ophthalmology. ,vol. 79, pp. 768- 775 ,(1975) , 10.1016/0002-9394(75)90735-7
Rohit Varma, George L Spaeth, William C Steinmann, L Jay Katz, Agreement Between Clinicians and an Image Analyzer in Estimating Cup-to-Disc Ratios Archives of Ophthalmology. ,vol. 107, pp. 526- 529 ,(1989) , 10.1001/ARCHOPHT.1989.01070010540027
NOBUO AOKI, HIROSHI AOKI, YOSHIYUKI OHNO, NORIHIKO HAYAKAWA, RYO KONDO, HIROSHI OKADA, EPIDEMIOLOGICAL EVALUATION OF FUNDUSCOPIC FINDINGS IN CEREBROVASCULAR DISEASES : III. OBSERVER VARIABILITY AND REPRODUCIBILITY FOR FUNDUSCOPIC FINDINGS : Original Articles written in English Japanese Circulation Journal-english Edition. ,vol. 41, pp. 11- 17 ,(1977) , 10.1253/JCJ.41.11
James M. Tielsch, Joanne Katz, Harry A. Quigley, Neil R. Miller, Alfred Sommer, Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics Ophthalmology. ,vol. 95, pp. 350- 356 ,(1988) , 10.1016/S0161-6420(88)33177-5
Barbara E.K. Klein, Yvonne L. Magli, Karen A. Richie, Scot E. Moss, Stacy M. Meuer, Ronald Klein, Quantitation of Optic Disc Cupping Ophthalmology. ,vol. 92, pp. 1654- 1656 ,(1985) , 10.1016/S0161-6420(85)34085-X
Benjamin Felson, W. K. C. Morgan, Leonard J. Bristol, Eugene P. Pendergrass, Edgar L. Dessen, Otha W. Linton, Robert B. Reger, Observations on the results of multiple readings of chest films in coal miners' pneumoconiosis. Radiology. ,vol. 109, pp. 19- 23 ,(1973) , 10.1148/109.1.19
Alfred Sommer, Irvin Pollack, A Edward Maumenee, Optic Disc Parameters and Onset of Glaucomatous Field Loss: I. Methods and Progressive Changes in Disc Morphology Archives of Ophthalmology. ,vol. 97, pp. 1444- 1448 ,(1979) , 10.1001/ARCHOPHT.1979.01020020106002
Barbara E.K. Klein, Scot E. Moss, Yvonne L. Magli, Ronald Klein, Judyth C. Johnson, Harry Roth, Optic Disc Cupping as Clinically Estimated from Photographs Ophthalmology. ,vol. 94, pp. 1481- 1483 ,(1987) , 10.1016/S0161-6420(87)33265-8