Detection of blood perfusion

作者: P.G. Krause , A.H. Tewfik , J.F. Greenleaf

DOI: 10.1109/ICIP.1999.822882

关键词:

摘要: Ultrasound detection of capillary blood flow is difficult as provides a weak backscattered signal with small Doppler shift. To aid in the such signals, new algorithm introduced exploiting two powerful ideas. First, receiver developed by creating subspaces corresponding to expected and clutter signals. It then exploits fact that some basis vectors are very nearly perpendicular. By projecting input data onto perpendicular components subspace sensitive detector can be realized. Secondly, coherently sums inputs from several angles. In vitro ultrasound collected applied detector. The utilizing multiple angles shown detecting experimental down 5 mm/sec 6 mm diameter channel.

参考文章(10)
U. Midtgard, J. R. Hales, A. A. Fawcett, P. Sejrsen, Skin blood flow in sheep: comparison of xenon-133 washout and radioactive microsphere techniques Journal of Applied Physiology. ,vol. 63, pp. 962- 968 ,(1987) , 10.1152/JAPPL.1987.63.3.962
P.N. Burns, M. Halliwell, P.N.T. Wells, A.J. Webb, Ultrasonic Doppler studies of the breast Ultrasound in Medicine and Biology. ,vol. 8, pp. 127- 143 ,(1982) , 10.1016/0301-5629(82)90092-8
Gert E. Nilsson, Torsten Tenland, P. Ake Oberg, Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow IEEE Transactions on Biomedical Engineering. ,vol. BME-27, pp. 597- 604 ,(1980) , 10.1109/TBME.1980.326582
J M Rubin, R O Bude, P L Carson, R L Bree, R S Adler, Power Doppler US : a potentially useful alternative to mean frequency-based color Doppler US Radiology. ,vol. 190, pp. 853- 856 ,(1994) , 10.1148/RADIOLOGY.190.3.8115639
A. H. Tewfik, H. Garnaoui, Multigrid implementation of a hypothesis-testing approach to parametric blur identification and image restoration Journal of The Optical Society of America A-optics Image Science and Vision. ,vol. 8, pp. 1026- 1037 ,(1991) , 10.1364/JOSAA.8.001026
C M Rigsby, P N Burns, G G Weltin, B Chen, M Bia, K J Taylor, Doppler signal quantitation in renal allografts: comparison in normal and rejecting transplants, with pathologic correlation. Radiology. ,vol. 162, pp. 39- 42 ,(1987) , 10.1148/RADIOLOGY.162.1.3538151
K.W. Ferrara, V.R. Algazi, A new wideband spread target maximum likelihood estimator for blood velocity estimation. I. Theory IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control. ,vol. 38, pp. 1- 16 ,(1991) , 10.1109/58.67829
Gene H Golub, Charles F Van Loan, Matrix computations ,(1983)