作者: Habib Razmi , Esmaeil Habibi
DOI: 10.1016/J.ELECTACTA.2010.07.081
关键词:
摘要: Abstract This paper reports the use of a carbon ceramic electrode as highly-porous substrate for electrochemical formation cobalt oxide nanoparticles. The electrocatalyst was characterized by energy dispersive X-ray (EDX) spectroscopy, scanning electron microscopy (SEM) and cyclic voltammetry techniques, it used in homemade flow injection analysis (FIA) system acetaminophen determination using 0.1 M KOH carrier solution. rate constant (ks) charge transfer coefficient (α) were calculated exchange reaction modified film. kinetic parameters mechanism electrooxidation at surface studied chronoamperometry. effects working potential on performance FIA studied. Under optimized conditions, response due to electrocatalytic oxidation 450 mV (vs. SCE) is proportional concentration over 5–35 μM range with an associated detection limit (S/N = 3) 0.37 μM sensitivity 0.0296 μA/μM. relative standard deviation (RSD) 1.6% eight replicate measurements. determine content tablet samples.