Current harmonics generated by electric vehicle battery chargers

作者: S.H. Berisha , G.G. Karady , R. Ahmad , R. Hobbs , D. Karner

DOI: 10.1109/PEDES.1996.539678

关键词:

摘要: This paper presents the results and analysis of data collected in three groups electric vehicle battery chargers during consecutive years: 1993, 1994, 1995. The first group consisted 27 chargers. generated harmonics these are significant. Total current harmonic distortion was range from 20.2% to over 112.4% with an average 50.1%. second seven on-board production-type vehicles. vehicles lower. total is 17.12% 101.81% 45.17%. third tested 1995 four production latest technology implemented so very low. 3.720% 7.18% 6.12%. shows that charger manufacturers have significantly improved charging terms harmonics.

参考文章(1)
George G. Karady, Shahin H. Berisha, Tracy Blake, Ray Hobbs, Power Quality Problems at Electric Vehicle's Charging Station SAE Technical Paper Series. ,vol. 103, pp. 252- 258 ,(1994) , 10.4271/940297