Orthogonal cutting of cancellous bone with application to the harvesting of bone autograft.

作者: Sharif F.F. Malak , Iain A. Anderson

DOI: 10.1016/J.MEDENGPHY.2007.02.010

关键词:

摘要: Autogenous bone graft harvesting results in cell death within the graft and trauma at the donor site. The latter can be mitigated by using minimally invasive tools and techniques, while cell morbidity may be reduced by improving cutter design and cutting parameters. We have performed orthogonal cutting experiments on bovine cancellous bone samples, to gain a basic understanding of the cutting mechanism and to determine design guidelines for tooling. Measurements were performed at cutting speeds from 11.2 to 5000mm/min, with tool …

参考文章(34)
J.L. Russell, J.E. Block, Surgical harvesting of bone graft from the ilium: point of view. Medical Hypotheses. ,vol. 55, pp. 474- 479 ,(2000) , 10.1054/MEHY.2000.1095
S. Saha, S. Pal, J. A. Albright, Surgical Drilling: Design and Performance of an Improved Drill Journal of Biomechanical Engineering-transactions of The Asme. ,vol. 104, pp. 245- 252 ,(1982) , 10.1115/1.3138356
LAWRENCE T. KURZ, STEVEN R. GARFIN, ROBERT E. BOOTH, Harvesting Autogenous Iliac Bone Grafts: A Review of Complications and Techniques Spine. ,vol. 14, pp. 1324- 1331 ,(1989) , 10.1097/00007632-198912000-00009
Sharif F.F. Malak, Iain A. Anderson, Orthogonal cutting of polyurethane foam International Journal of Mechanical Sciences. ,vol. 47, pp. 867- 883 ,(2005) , 10.1016/J.IJMECSCI.2005.02.002
M.T Hillery, I Shuaib, Temperature effects in the drilling of human and bovine bone Journal of Materials Processing Technology. ,vol. 92, pp. 302- 308 ,(1999) , 10.1016/S0924-0136(99)00155-7
H.C. Shin, Y.S. Yoon, Bone temperature estimation during orthopaedic round bur milling operations. Journal of Biomechanics. ,vol. 39, pp. 33- 39 ,(2006) , 10.1016/J.JBIOMECH.2004.11.004
P. Kessler, M. Thorwarth, A. Bloch-Birkholz, E. Nkenke, F.W. Neukam, Harvesting of bone from the iliac crest--comparison of the anterior and posterior sites. British Journal of Oral & Maxillofacial Surgery. ,vol. 43, pp. 51- 56 ,(2005) , 10.1016/J.BJOMS.2004.08.026
Mohamed Sharawy, Carl E. Misch, Norman Weller, Sherif Tehemar, Heat generation during implant drilling: the significance of motor speed. Journal of Oral and Maxillofacial Surgery. ,vol. 60, pp. 1160- 1169 ,(2002) , 10.1053/JOMS.2002.34992