Needle-type extraction device for the purge and trap analysis of 23 volatile organic compounds in tap water.

作者: Ikuo Ueta , Nurhafizza Abd Razak , Ayako Mizuguchi , Susumu Kawakubo , Yoshihiro Saito

DOI: 10.1016/J.CHROMA.2013.07.011

关键词:

摘要: We developed a rapid determination technique for trace volatile organic compounds (VOCs) in tap water by introducing novel needle-type extraction device coupled to purge-and-trap method. To extract wide range of VOCs, new needle containing particles divinylbenzene and activated carbon was this study. During the active sampling headspace gas glass vial needle, pure N2 used purging aqueous sample. After optimization several experimental parameters, such as addition salt conditions dry desorption, performance method evaluated 23 VOCs that are typically found samples. The quantification limits were 0.6 μg/L 1,1-dichloroethylene less than 0.5 other with good repeatability being confirmed all target compounds. Taking advantage excellent recovery real samples carried out successfully. Because does not require sample heating and/or cryogenic focusing, simple analyses can be performed along satisfactory sensitivity typical

参考文章(29)
Janusz Pawliszyn, Weiqiang Zhan, Heather L. Lord, Fundamentals and applications of needle trap devices: A critical review Analytica Chimica Acta. ,vol. 677, pp. 3- 18 ,(2010) , 10.1016/J.ACA.2010.06.020
Jamie M. Warren, Janusz Pawliszyn, Development and evaluation of needle trap device geometry and packing methods for automated and manual analysis. Journal of Chromatography A. ,vol. 1218, pp. 8982- 8988 ,(2011) , 10.1016/J.CHROMA.2011.10.017
Monica Alonso, Laura Cerdan, Anna Godayol, Enriqueta Anticó, Juan M. Sanchez, Headspace needle-trap analysis of priority volatile organic compounds from aqueous samples: application to the analysis of natural and waste waters. Journal of Chromatography A. ,vol. 1218, pp. 8131- 8139 ,(2011) , 10.1016/J.CHROMA.2011.09.042
Mohamed Abdel-Rehim, Recent advances in microextraction by packed sorbent for bioanalysis Journal of Chromatography A. ,vol. 1217, pp. 2569- 2580 ,(2010) , 10.1016/J.CHROMA.2009.09.053
Ikuo Ueta, Ayako Mizuguchi, Koji Fujimura, Susumu Kawakubo, Yoshihiro Saito, Novel sample preparation technique with needle-type micro-extraction device for volatile organic compounds in indoor air samples. Analytica Chimica Acta. ,vol. 746, pp. 77- 83 ,(2012) , 10.1016/J.ACA.2012.08.014
Yoshihiro Saito, Ikuo Ueta, Kenzo Kotera, Mitsuhiro Ogawa, Hiroo Wada, Kiyokatsu Jinno, In-needle extraction device designed for gas chromatographic analysis of volatile organic compounds Journal of Chromatography A. ,vol. 1106, pp. 190- 195 ,(2006) , 10.1016/J.CHROMA.2005.08.048