Spectrophotometric study of the relationship between body porcelain color and applied metallic oxide pigments

作者: Todd W. Lund , William B. Schwabacher , Richard J. Goodkind

DOI: 10.1016/0022-3913(85)90158-1

关键词:

摘要: I t is unlikely that anyone able to measure objectively a porcelain restoration by number represents how lifelike it appears. The restorative dentist must assess the elements cause subjective impression of “naturalness” in tooth fabricate will produce natural effect. relies on external and internal tinting techniques modify color existing restorations. teeth vitro has been measured several studies, some using spectrophotometer.le3 colors both available dental porcelains shade guides have similarly measured.’ In final analysis, however, dentist’s judgment determines restoration. To discuss from an objective point view,

参考文章(9)
Max Saltzman, Fred W. Billmeyer, Principles of color technology ,(1967)
MELVIN L. RUBIN, GORDON L. WALLS, Fundamentals of visual science Optometry and Vision Science. ,vol. 47, pp. 407- ,(1970) , 10.1097/00006324-197005000-00021
W. D. Wright, The measurement of colour ,(1944)
Günter Wyszecki, Kenneth L. Kelly, V. S. Stiles, Color Science. Concepts and Methods, Quantitative Data and Formulas ,(1967)
Herman Z. Cummins, Samuel J. Williamson, John N. Kidder, Light and Color in Nature and Art ,(1983)
Robert C. Sproull, Color matching in dentistry. Part II. Practical applications of the organization of color Journal of Prosthetic Dentistry. ,vol. 29, pp. 556- 566 ,(1973) , 10.1016/0022-3913(73)90036-X
Jack D Preston, Color science and dental art ,(1980)