摘要: An electrochemical immunosensor based on interdigitated array microelectrodes (IDAMs) was developed for sensitive, specific and rapid detection of chlorpyrifos. Anti-chlorpyrifos monoclonal antibodies were orientedly immobilized onto the gold microelectrode surface through protein A. Chlorpyrifos then captured by antibody, resulting in an impedance change IDAMs surface. Electrochemical spectroscopy used conjunction with fabricated sensor to detect Under optimum conditions, value chlorpyrifos proportional its concentrations range 100–105 ng/mL. The limit found be 0.014 ng/mL proposed could as a screening method pesticide determination analysis environmental, agricultural pharmaceutical samples due rapidity, sensitivity low cost.

参考文章(34)
Gongjun Yang, Wenjie Jin, Liping Wu, Qianqian Wang, Hongxia Shao, Aijian Qin, Bing Yu, Dongming Li, Baoliang Cai, Development of an impedimetric immunosensor for the determination of 3-amino-2-oxazolidone residue in food samples Analytica Chimica Acta. ,vol. 706, pp. 120- 127 ,(2011) , 10.1016/J.ACA.2011.08.018
Javier Ramón-Azcón, Enrique Valera, Ángel Rodríguez, Alejandro Barranco, Begoña Alfaro, Francisco Sanchez-Baeza, M.-Pilar Marco, An impedimetric immunosensor based on interdigitated microelectrodes (IDμE) for the determination of atrazine residues in food samples Biosensors and Bioelectronics. ,vol. 23, pp. 1367- 1373 ,(2008) , 10.1016/J.BIOS.2007.12.010
Marinella Farré, Lina Kantiani, Damià Barceló, Advances in immunochemical technologies for analysis of organic pollutants in the environment Trends in Analytical Chemistry. ,vol. 26, pp. 1100- 1112 ,(2007) , 10.1016/J.TRAC.2007.10.004
Xiaohui Tang, Denis Flandre, Jean-Pierre Raskin, Yannick Nizet, Luis Moreno-Hagelsieb, Rémi Pampin, Laurent A. Francis, A new interdigitated array microelectrode-oxide-silicon sensor with label-free, high sensitivity and specificity for fast bacteria detection Sensors and Actuators B-chemical. ,vol. 156, pp. 578- 587 ,(2011) , 10.1016/J.SNB.2011.02.002
Nirmal Prabhakar, G. Sumana, Kavita Arora, Harpal Singh, B.D. Malhotra, Improved electrochemical nucleic acid biosensor based on polyaniline-polyvinyl sulphonate Electrochimica Acta. ,vol. 53, pp. 4344- 4350 ,(2008) , 10.1016/J.ELECTACTA.2007.12.062
E. Mauriz, A. Calle, L.M. Lechuga, J. Quintana, A. Montoya, J.J. Manclús, Real-time detection of chlorpyrifos at part per trillion levels in ground, surface and drinking water samples by a portable surface plasmon resonance immunosensor Analytica Chimica Acta. ,vol. 561, pp. 40- 47 ,(2006) , 10.1016/J.ACA.2005.12.069
Ines Streitner, Markus Goldhofer, Sungbo Cho, Hagen Thielecke, Ralf Kinscherf, Florian Streitner, Jürgen Metz, Karl K. Haase, Martin Borggrefe, Tim Suselbeck, Electric impedance spectroscopy of human atherosclerotic lesions Atherosclerosis. ,vol. 206, pp. 464- 468 ,(2009) , 10.1016/J.ATHEROSCLEROSIS.2009.03.015
Charles Timchalk, James A. Campbell, Guodong Liu, Yuehe Lin, Ahmed A. Kousba, Development of a non-invasive biomonitoring approach to determine exposure to the organophosphorus insecticide chlorpyrifos in rat saliva. Toxicology and Applied Pharmacology. ,vol. 219, pp. 217- 225 ,(2007) , 10.1016/J.TAAP.2006.10.002