Shunt Active Power Filter

作者: Germán A. Ramos , Ramon Costa-Castelló , Josep M. Olm

DOI: 10.1007/978-3-642-37778-5_7

关键词:

摘要: Shunt active power filters have been introduced as a way to overcome the quality problems caused by nonlinear and reactive loads [9, 14, 23]. These electronics devices are designed with goal of obtaining factor close 1 achieving current harmonics compensation [5, 6, 15]. The usual approaches 15] for control shunt based on two hierarchical loops: an inner one that assures desired outer in charge determining its required shape appropriate balance well. structure followed this Chapter is [7], which controller composed feedforward action provides very fast transient response, also feedback loop includes odd-harmonic repetitive yields closed-loop stability good harmonic correction performance. In turn, law appropriated computation amplitude sinusoidal network and, aiming at robustness improvement, combined including analytically tuned PI controller.

参考文章(21)
Marco Liserre, Remus Teodorescu, Pedro Rodriguez, Grid Converters for Photovoltaic and Wind Power Systems ,(2011)
Sigrid Mechthild Bolik, Modelling and Analysis of Variable Speed Wind Turbines with Induction Generator during Grid Fault Institut for Energiteknik, Aalborg Universitet. ,(2004)
P. Mattavelli, A closed-loop selective harmonic compensation for active filters IEEE Transactions on Industry Applications. ,vol. 37, pp. 81- 89 ,(2001) , 10.1109/28.903130
Dennis Bruijnen, René van de Molengraft, Maarten Steinbuch, EFFICIENT IIR NOTCH FILTER DESIGN VIA MULTIRATE FILTERING TARGETED AT HARMONIC DISTURBANCE REJECTION IFAC Proceedings Volumes. ,vol. 39, pp. 318- 323 ,(2006) , 10.3182/20060912-3-DE-2911.00057
Sergio Galeani, Sophie Tarbouriech, Matthew Turner, Luca Zaccarian, A Tutorial on Modern Anti-Windup Design European Journal of Control. ,vol. 15, pp. 418- 440 ,(2009) , 10.3166/EJC.15.418-440
P. Apkarian, R.J. Adams, Advanced gain-scheduling techniques for uncertain systems IEEE Transactions on Control Systems and Technology. ,vol. 6, pp. 21- 32 ,(1998) , 10.1109/87.654874
D. Sbarbaro, M. Tomizuka, B. León de la Barra, Repetitive Control System Under Actuator Saturation and Windup Prevention Journal of Dynamic Systems Measurement and Control-transactions of The Asme. ,vol. 131, pp. 044505- ,(2009) , 10.1115/1.3117207
S. Buso, L. Malesani, P. Mattavelli, Comparison of current control techniques for active filter applications IEEE Transactions on Industrial Electronics. ,vol. 45, pp. 722- 729 ,(1998) , 10.1109/41.720328