Update on Treating High Myopia With Implantable Collamer Lenses.

作者: Xiaoying Wang , Xingtao Zhou

DOI: 10.1097/APO.0000000000000235

关键词:

摘要: The purpose of this article is to provide updates on the treatment high myopia with implantable collamer lens (ICL). ICL has become an important technique used in intraocular refractive surgery. With improvements material, design, and application, good efficacy, predictability, long-term safety stability, manageable complications, reversibility. More more surgeons are taking note ICL. This reviews material characteristics latest designs along clinical applications, visual quality, future development.

参考文章(52)
Kazutaka Kamiya, Mari Komatsu, Kimiya Shimizu, Factors Affecting Vaulting After Implantable Collamer Lens Implantation Journal of Refractive Surgery. ,vol. 25, pp. 259- 264 ,(2009) , 10.3928/1081597X-20090301-04
H. Bleckmann, J. Jørgensen, I. Lamcke, R. Keuch, Bioptik Der Ophthalmologe. ,vol. 99, pp. 936- 940 ,(2002) , 10.1007/S00347-002-0664-3
Jonathan M Davidorf, Giselle Ricur, Roberto Zaldivar, Virginia Piezzi, Susana Oscherow, Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia. Journal of Refractive Surgery. ,vol. 15, pp. 299- 308 ,(1999) , 10.3928/1081-597X-19990501-04
Tomás Moya, Jaime Javaloy, Robert Montés-Micó, Jaime Beltrán, Gonzalo Muñoz, Raúl Montalbán, Implantable Collamer Lens for Myopia: Assessment 12 Years After Implantation. Journal of Refractive Surgery. ,vol. 31, pp. 548- 556 ,(2015) , 10.3928/1081597X-20150727-05
Jodhbir S Mehta, Leonard H Yuen, Lakhbir S Mengher, Miltos Papathanassiou, Bruce DS Allan, Correcting post-keratoplasty anisometropia with the implantable collamer phakic intraocular lens. Clinical and Experimental Ophthalmology. ,vol. 38, pp. 764- 767 ,(2010) , 10.1111/J.1442-9071.2010.02348.X
Carlos Lisa, Miguel Naveiras, Belén Alfonso-Bartolozzi, Lurdes Belda-Salmerón, Robert Montés-Micó, José F. Alfonso, Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct myopia: One-year follow-up Journal of Cataract and Refractive Surgery. ,vol. 41, pp. 1153- 1159 ,(2015) , 10.1016/J.JCRS.2014.10.030
MahfouthA Bamashmus, SeddiqueA Al-Salahim, NabilA Tarish, MahmoudF Saleh, HatemA Mahmoud, MohamedF Elanwar, MohamedA Awadalla, Posterior vitreous detachment and retinal detachment after implantation of the Visian phakic implantable collamer lens. Middle East African Journal of Ophthalmology. ,vol. 20, pp. 327- 331 ,(2013) , 10.4103/0974-9233.120019
Kazutaka Kamiya, Akihito Igarashi, Kimiya Shimizu, Kazuhiro Matsumura, Mari Komatsu, Visual performance after posterior chamber phakic intraocular lens implantation and wavefront-guided laser in situ keratomileusis for low to moderate myopia. American Journal of Ophthalmology. ,vol. 153, pp. 1178- ,(2012) , 10.1016/J.AJO.2011.12.005
Akihito Igarashi, Kimiya Shimizu, Kazutaka Kamiya, Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia American Journal of Ophthalmology. ,vol. 157, pp. 532- 539 ,(2014) , 10.1016/J.AJO.2013.11.006