Advances in High-Field BOLD fMRI

作者: Markus Barth , Benedikt A. Poser

DOI: 10.3390/MA4111941

关键词:

摘要: This review article examines the current state of BOLD fMRI at a high magnetic field strength 7 Tesla. The following aspects are covered: short description contrast, spatial and temporal resolution, sensitivity, localization specificity, technical challenges as well an outlook on future developments given. It is shown that main performing strengths-namely development array coils, imaging sequences parallel reconstruction-have been solved successfully. combination these has lead to availability high-resolution protocols able cover whole brain with repetition time (TR) shorter than 3 s. structural information available from images itself already very detailed, which helps co-localize structure function. Potential applications include whole-brain connectivity analysis laminar resolution single subject examinations.

参考文章(70)
Rolf Gruetter, Automatic, localized in vivo adjustment of all first- and second-order shim coils. Magnetic Resonance in Medicine. ,vol. 29, pp. 804- 811 ,(1993) , 10.1002/MRM.1910290613
Elke R. Gizewski, Armin de Greiff, Stefan Maderwald, Dagmar Timmann, Michael Forsting, Mark E. Ladd, fMRI at 7 T: whole-brain coverage and signal advantages even infratentorially? NeuroImage. ,vol. 37, pp. 761- 768 ,(2007) , 10.1016/J.NEUROIMAGE.2007.06.005
Fa-Hsuan Lin, Thomas Witzel, Wei-Tang Chang, Kevin Wen-Kai Tsai, Yen-Hsiang Wang, Wen-Jui Kuo, John W. Belliveau, K-space reconstruction of magnetic resonance inverse imaging (K-InI) of human visuomotor systems. NeuroImage. ,vol. 49, pp. 3086- 3098 ,(2010) , 10.1016/J.NEUROIMAGE.2009.11.016
H.M. Duvernoy, S. Delon, J.L. Vannson, Cortical blood vessels of the human brain Brain Research Bulletin. ,vol. 7, pp. 519- 579 ,(1981) , 10.1016/0361-9230(81)90007-1
Benedikt A. Poser, David G. Norris, Investigating the benefits of multi-echo EPI for fMRI at 7 T NeuroImage. ,vol. 45, pp. 1162- 1172 ,(2009) , 10.1016/J.NEUROIMAGE.2009.01.007
Steen Moeller, Essa Yacoub, Cheryl A. Olman, Edward Auerbach, John Strupp, Noam Harel, Kâmil Uğurbil, Multiband Multislice GE-EPI at 7 Tesla, With 16-Fold Acceleration Using Partial Parallel Imaging With Application to High Spatial and Temporal Whole-Brain FMRI Magnetic Resonance in Medicine. ,vol. 63, pp. 1144- 1153 ,(2010) , 10.1002/MRM.22361
K.J. Worsley, C.H. Liao, J. Aston, V. Petre, G.H. Duncan, F. Morales, A.C. Evans, A general statistical analysis for fMRI data. NeuroImage. ,vol. 15, pp. 1- 15 ,(2000) , 10.1006/NIMG.2001.0933
C. Triantafyllou, R.D. Hoge, G. Krueger, C.J. Wiggins, A. Potthast, G.C. Wiggins, L.L. Wald, Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters. NeuroImage. ,vol. 26, pp. 243- 250 ,(2005) , 10.1016/J.NEUROIMAGE.2005.01.007