Comparison of myelin water fraction from multiecho T2decay curve and steady-state methods

作者: Jing Zhang , Shannon H. Kolind , Cornelia Laule , Alex L. MacKay

DOI: 10.1002/MRM.25125

关键词:

摘要: Purpose Myelin water fraction is conventionally measured from the T2 decay curve. Recently, a steady-state approach entitled multicomponent-driven equilibrium single pulse observation of T1/T2 (mcDESPOT) was employed for myelin mapping. However, no direct comparison between established multiecho relaxation method and mcDESPOT has been performed. Methods Gradient spin echo (GRASE) acquired curve measurements were 10 healthy volunteers using 3T MRI. We compared fraction, transmit radio frequency field (B1), T2's intra- extracellular obtained both methods. Results For all brain regions examined, fractions significantly higher than those GRASE. B1 maps qualitatively similar GRASE mcDESPOT, but multicomponent times different. To investigate effect exchange, data analyzed with without exchange. When exchange turned off, roughly consistent results; however, derived still GRASE. Conclusion Myelin values cannot be considered to equivalent approaches. Magn Reson Med 73:223–232, 2015. © 2014 Wiley Periodicals, Inc.

参考文章(37)
Sandra M. Sirrs, Cornelia Laule, Burkhard Mädler, Elana E. Brief, Sumia A. Tahir, Carole Bishop, Alex L. MacKay, Normal-appearing white matter in patients with phenylketonuria: water content, myelin water fraction, and metabolite concentrations. Radiology. ,vol. 242, pp. 236- 243 ,(2007) , 10.1148/RADIOL.2421051758
Thorarin A. Bjarnason, Cheryl R. McCreary, Jeff F. Dunn, J. Ross Mitchell, Quantitative T2 analysis: the effects of noise, regularization, and multivoxel approaches. Magnetic Resonance in Medicine. ,vol. 63, pp. 212- 217 ,(2009) , 10.1002/MRM.22173
G.J. Stanisz, A. Kecojevic, M.J. Bronskill, R.M. Henkelman, Characterizing white matter with magnetization transfer and T2 Magnetic Resonance in Medicine. ,vol. 42, pp. 1128- 1136 ,(1999) , 10.1002/(SICI)1522-2594(199912)42:6<1128::AID-MRM18>3.0.CO;2-9
Thanh D. Nguyen, Cynthia Wisnieff, Mitchell A. Cooper, Dushyant Kumar, Ashish Raj, Pascal Spincemaille, Yi Wang, Tim Vartanian, Susan A. Gauthier, T2prep three‐dimensional spiral imaging with efficient whole brain coverage for myelin water quantification at 1.5 tesla Magnetic Resonance in Medicine. ,vol. 67, pp. 614- 621 ,(2012) , 10.1002/MRM.24128
Yijing Wu, Andrew L. Alexander, John O. Fleming, Ian D. Duncan, Aaron S. Field, Myelin water fraction in human cervical spinal cord in vivo. Journal of Computer Assisted Tomography. ,vol. 30, pp. 304- 306 ,(2006) , 10.1097/00004728-200603000-00026
Kenneth P Whittall, Alexander L MacKay, Quantitative interpretation of NMR relaxation data Journal of Magnetic Resonance. ,vol. 84, pp. 134- 152 ,(1989) , 10.1016/0022-2364(89)90011-5
Shannon H. Kolind, Sean C. Deoni, Rapid three-dimensional multicomponent relaxation imaging of the cervical spinal cord. Magnetic Resonance in Medicine. ,vol. 65, pp. 551- 556 ,(2011) , 10.1002/MRM.22634