Super-size me: adipose tissue-equivalent additions for anthropomorphic phantoms.

作者: Ryan F. Fisher , David E. Hintenlang

DOI: 10.1120/JACMP.V15I6.5007

关键词:

摘要: Physical anthropomorphic phantoms have been utilized for a variety of dosimet- ric studies across range procedures utilizing diagnostic imaging equipment. Unfortunately, these are often limited to single reference size, which may not be representative the patient population at large. This work set out develop an adipose tissue-equivalent substitute material that could used create low cost physical additions existing phantoms. Using commercially available products, methodology was developed accomplish this, and addition built 90th percentile by weight phantom from 50th model. can easily expand utility in order better represent patients various body morphologies, investigate effects size procedures.

参考文章(8)
Lynne M. Hurwitz, Terry T. Yoshizumi, Philip C. Goodman, Donald P. Frush, Giao Nguyen, Greta Toncheva, Carolyn Lowry, Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. Journal of Computer Assisted Tomography. ,vol. 31, pp. 544- 549 ,(2007) , 10.1097/RCT.0B013E31802D3DD2
Robert J Staton, A Kyle Jones, Choonik Lee, David E Hintenlang, Manuel M Arreola, Jonathon L Williams, Wesley E Bolch, None, A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography. Medical Physics. ,vol. 33, pp. 3283- 3289 ,(2006) , 10.1118/1.2256687
Monica W.K. Kan, Lucullus H.T. Leung, Wicger Wong, Nelson Lam, RADIATION DOSE FROM CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIATION THERAPY International Journal of Radiation Oncology Biology Physics. ,vol. 70, pp. 272- 279 ,(2008) , 10.1016/J.IJROBP.2007.08.062
James F. Winslow, Daniel E. Hyer, Ryan F. Fisher, Christopher J. Tien, David E. Hintenlang, Construction of anthropomorphic phantoms for use in dosimetry studies. Journal of Applied Clinical Medical Physics. ,vol. 10, pp. 195- 204 ,(2009) , 10.1120/JACMP.V10I3.2986
Daniel E. Hyer, Christopher F. Serago, Siyong Kim, Jonathan G. Li, David E. Hintenlang, An organ and effective dose study of XVI and OBI cone-beam CT systems Journal of Applied Clinical Medical Physics. ,vol. 11, pp. 181- 197 ,(2010) , 10.1120/JACMP.V11I2.3183
Tohru Yoshizumi, Tadashi Nakamura, Mitsukazu Yamane, Abdul Hasan M. Waliul Islam, Masakazu Menju, Kouichi Yamasaki, Takeshi Arai, Kazuaki Kotani, Tohru Funahashi, Shizuya Yamashita, Yuji Matsuzawa, Abdominal fat: standardized technique for measurement at CT. Radiology. ,vol. 211, pp. 283- 286 ,(1999) , 10.1148/RADIOLOGY.211.1.R99AP15283
Perry B. Johnson, Scott R. Whalen, Michael Wayson, Badal Juneja, Choonsik Lee, Wesley E. Bolch, Hybrid Patient-Dependent Phantoms Covering Statistical Distributions of Body Morphometry in the U.S. Adult and Pediatric Population Proceedings of the IEEE. ,vol. 97, pp. 2060- 2075 ,(2009) , 10.1109/JPROC.2009.2032855