Zwei direkte Druckmessverfahren zur Bestimmung des intraabdominellen Drucks im Vergleich zur Blasendruckmessung im Schweinemodell

作者: Ranjith Elam , Alexander Schachtrupp

DOI:

关键词:

摘要:

参考文章(45)
Amelia S. Munsterman, R. Reid Hanson, Comparison of direct and indirect methods of intra-abdominal pressure measurement in normal horses. Journal of Veterinary Emergency and Critical Care. ,vol. 19, pp. 545- 553 ,(2009) , 10.1111/J.1476-4431.2009.00482.X
J. Otto, D. Kaemmer, J. Höer, M. Jansen, V. Schumpelick, M. Strik, R. Kuhlen, A. Schachtrupp, Bedeutung des abdominellen Kompartmentsyndroms in Deutschland Anaesthesist. ,vol. 58, pp. 607- 610 ,(2009) , 10.1007/S00101-009-1541-0
Gregory F. Dakin, Richard Nahouraii, Paolo Gentileschi, Subhash Kini, Michel Gagner, Subcutaneous endoscopic fasciotomy in a porcine model of abdominal compartment syndrome: a feasibility study. Journal of Laparoendoscopic & Advanced Surgical Techniques. ,vol. 14, pp. 339- 344 ,(2004) , 10.1089/LAP.2004.14.339
Pertti K. Suominen, Mikko P. Pakarinen, Paula Rautiainen, Ilkka Mattila, Heikki Sairanen, Comparison of direct and intravesical measurement of intraabdominal pressure in children Journal of Pediatric Surgery. ,vol. 41, pp. 1381- 1385 ,(2006) , 10.1016/J.JPEDSURG.2006.04.030
M. Sugrue, M. D. Buist, A. Lee, D. J. Sanchez, K. M. Hillman, Intra-abdominal pressure measurement using a modified nasogastric tube: Description and validation of a new technique Intensive Care Medicine. ,vol. 20, pp. 588- 590 ,(1994) , 10.1007/BF01705728
Christoph Meier, Claudio Contaldo, Rene Schramm, Joerg H. Holstein, Juerg Hamacher, Michaela Amon, Guido A. Wanner, Otmar Trentz, Michael D. Menger, Microdialysis of the rectus abdominis muscle for early detection of impending abdominal compartment syndrome Intensive Care Medicine. ,vol. 33, pp. 1434- 1443 ,(2007) , 10.1007/S00134-007-0725-9
Annika Reintam, Pille Parm, Reet Kitus, Hartmut Kern, Joel Starkopf, Primary and secondary intra-abdominal hypertension--different impact on ICU outcome. Intensive Care Medicine. ,vol. 34, pp. 1624- 1631 ,(2008) , 10.1007/S00134-008-1134-4
F. Gudmundsson, A. Viste, H. Gislason, K. Svanes, Comparison of different methods for measuring intra-abdominal pressure Intensive Care Medicine. ,vol. 28, pp. 509- 514 ,(2002) , 10.1007/S00134-001-1187-0
Andrew W. Kirkpatrick, Robert Colistro, Kevin B. Laupland, Daniel L. Fox, David E. Konkin, Volker Kock, John R. Mayo, Savvas Nicolaou, Renal arterial resistive index response to intraabdominal hypertension in a porcine model* Critical Care Medicine. ,vol. 35, pp. 207- 213 ,(2007) , 10.1097/01.CCM.0000249824.48222.B7
J.J. De Waele, I. De laet, M.L.N.G. Malbrain, Rational intraabdominal pressure monitoring : How to do it? Acta Clinica Belgica. ,vol. 62, pp. 16- 25 ,(2007) , 10.1179/ACB.2007.62.S1.004