The effect of injection rate on time-resolved contrast-enhanced peripheral MRA.

作者: Timothy J. Carroll , Frank R. Korosec , J. Shannon Swan , Thomas F. Hany , Thomas M. Grist

DOI: 10.1002/JMRI.1200

关键词:

摘要: In contrast-enhanced (CE) magnetic resonance (MR) angiography (MRA), lower injection rates of a fixed contrast agent dose provide longer bolus at the expense intravascular signal. This study evaluated effect different in imaging vasculature extremities with time-resolved, CE MRA. three volunteers, 0.5, 1.5 and 3.0 mL/second were administered randomized order imaged two separate sessions. Contrast dynamics measured volunteers used computer simulations to confirm variations concentration as source vessel ringing blurring artifacts. To validate rate pathologic vessels, 37 patients peripheral vascular disease time-resolved technique using an 0.5 or retrospectively divided into groups. higher caused stronger modulation k-space resulted increased artifacts These results reproduced simulations. qualitative patient study, significantly less was observed injection-rate, without significant loss contrast. J. Magn. Reson. Imaging 2001;14:401–410. © 2001 Wiley-Liss, Inc.

参考文章(16)
E. Mark Haacke, Robert W. Brown, Michael R. Thompson, Ramesh Venkatesan, Yu Chung N Cheng, Magnetic Resonance Imaging: Physical Principles and Sequence Design ,(1999)
Jonas Svensson, J Stefan Petersson, Freddy Ståhlberg, Elna‐Marie Larsson, Peter Leander, Lars E Olsson, None, Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA. Journal of Magnetic Resonance Imaging. ,vol. 10, pp. 919- 928 ,(1999) , 10.1002/(SICI)1522-2586(199912)10:6<919::AID-JMRI3>3.0.CO;2-W
Vincent B. Ho, Peter L. Choyke, Thomas K.F. Foo, Maureen N. Hood, Donald L. Miller, Julianna M. Czum, Alex M. Aisen, Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. Journal of Magnetic Resonance Imaging. ,vol. 10, pp. 376- 388 ,(1999) , 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO;2-U
Martin R. Prince, E. Kent Yucel, John A. Kaufman, David C. Harrison, Stuart C. Geller, Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography Journal of Magnetic Resonance Imaging. ,vol. 3, pp. 877- 881 ,(1993) , 10.1002/JMRI.1880030614
YI WANG, PRISCILLA A. WINCHESTER, NEIL M. KHILNANI, HOWARD M. LEE, RICHARD WATTS, DAVID W. TROST, HARRY L. BUSH, K. CRAIG KENT, MARTIN R. PRINCE, Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries: combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions. Investigative Radiology. ,vol. 36, pp. 170- 177 ,(2001) , 10.1097/00004424-200103000-00006
J A Kaufman, D McCarter, S C Geller, A C Waltman, Two-dimensional time-of-flight MR angiography of the lower extremities: artifacts and pitfalls. American Journal of Roentgenology. ,vol. 171, pp. 129- 135 ,(1998) , 10.2214/AJR.171.1.9648776
Richard Frayne, Thomas M. Grist, J. Shannon Swan, Dana C. Peters, Frank R. Korosec, Charles A. Mistretta, 3D MR DSA: Effects of injection protocol and image masking† Journal of Magnetic Resonance Imaging. ,vol. 12, pp. 476- 487 ,(2000) , 10.1002/1522-2586(200009)12:3<476::AID-JMRI14>3.0.CO;2-F
Jeffrey H. Maki, Thomas L. Chenevert, Martin R. Prince, Three-dimensional contrast-enhanced MR angiography. Topics in Magnetic Resonance Imaging. ,vol. 8, pp. 322- 344 ,(1996) , 10.1097/00002142-199612000-00002
D. C. Look, D. R. Locker, Time Saving in Measurement of NMR and EPR Relaxation Times Review of Scientific Instruments. ,vol. 41, pp. 250- 251 ,(1970) , 10.1063/1.1684482
Neil M. Rofsky, Mark A. Adelman, MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease Radiology. ,vol. 214, pp. 325- 338 ,(2000) , 10.1148/RADIOLOGY.214.2.R00FE42325