Fluorescent aptasensor based on D-AMA/F-CSC for the sensitive and specific recognition of myoglobin

作者: Dongwei Miao , Dongkui Liu , Yanbo Zeng , Guobao Zhou , Wei Xie

DOI: 10.1016/J.SAA.2019.117714

关键词:

摘要: … A simple fluorescent aptasensor based on the interaction … aptasensor is inexpensive and easy to prepare and has high specificity and sensitivity for Mb. Given that the aptasensor …

参考文章(27)
Saima Anjum, Wenjing Qi, Wenyue Gao, Jianming Zhao, Saima Hanif, Aziz-ur-Rehman, Guobao Xu, Fabrication of biomembrane-like films on carbon electrodes using alkanethiol and diazonium salt and their application for direct electrochemistry of myoglobin Biosensors and Bioelectronics. ,vol. 65, pp. 159- 165 ,(2015) , 10.1016/J.BIOS.2014.10.037
Qing Wang, Xiaohan Yang, Xiaohai Yang, Fang Liu, Kemin Wang, Visual detection of myoglobin via G-quadruplex DNAzyme functionalized gold nanoparticles-based colorimetric biosensor Sensors and Actuators B-chemical. ,vol. 212, pp. 440- 445 ,(2015) , 10.1016/J.SNB.2015.02.040
Vinod Kumar, Munish Shorie, Ashok K. Ganguli, Priyanka Sabherwal, Graphene-CNT nanohybrid aptasensor for label free detection of cardiac biomarker myoglobin. Biosensors and Bioelectronics. ,vol. 72, pp. 56- 60 ,(2015) , 10.1016/J.BIOS.2015.04.089
Xianfeng Zhang, Xianming Kong, Wenjuan Fan, Xuezhong Du, Iminodiacetic acid-functionalized gold nanoparticles for optical sensing of myoglobin via Cu2+ coordination. Langmuir. ,vol. 27, pp. 6504- 6510 ,(2011) , 10.1021/LA200177E
James McCord, Richard M. Nowak, Peter A. McCullough, Craig Foreback, Steven Borzak, Glenn Tokarski, Michael C. Tomlanovich, Gordon Jacobsen, W. Douglas Weaver, Ninety-Minute Exclusion of Acute Myocardial Infarction By Use of Quantitative Point-of-Care Testing of Myoglobin and Troponin I Circulation. ,vol. 104, pp. 1483- 1488 ,(2001) , 10.1161/HC3801.096336
Qing Wang, Fang Liu, Xiaohai Yang, Kemin Wang, Hui Wang, Xin Deng, Sensitive point-of-care monitoring of cardiac biomarker myoglobin using aptamer and ubiquitous personal glucose meter. Biosensors and Bioelectronics. ,vol. 64, pp. 161- 164 ,(2015) , 10.1016/J.BIOS.2014.08.079
Oksana V. Gnedenko, Yury V. Mezentsev, Andrey A. Molnar, Andrey V. Lisitsa, Alexis S. Ivanov, Alexander I. Archakov, Highly sensitive detection of human cardiac myoglobin using a reverse sandwich immunoassay with a gold nanoparticle-enhanced surface plasmon resonance biosensor Analytica Chimica Acta. ,vol. 759, pp. 105- 109 ,(2013) , 10.1016/J.ACA.2012.10.053
Nicola Giaretta, Antonella M.A. Di Giuseppe, Martina Lippert, Augusto Parente, Antimo Di Maro, Myoglobin as marker in meat adulteration: a UPLC method for determining the presence of pork meat in raw beef burger. Food Chemistry. ,vol. 141, pp. 1814- 1820 ,(2013) , 10.1016/J.FOODCHEM.2013.04.124
Qiaoli Yue, Zhenghua Song, Assay of femtogram level nitrite in human urine using luminol–myoglobin chemiluminescence Microchemical Journal. ,vol. 84, pp. 10- 13 ,(2006) , 10.1016/J.MICROC.2006.03.005