作者: M. Kalantar , S.M. Mousavi G.
DOI: 10.1016/J.APENERGY.2010.02.019
关键词:
摘要: Abstract This paper presents dynamic behavior and simulation results in a stand-alone hybrid power generation system of wind turbine, microturbine, solar array battery storage. The consists 195 kW an 85 kW array; 230 kW microturbine 2.14 kAh lead acid pack optimized based on economic analysis using genetic algorithm (GA). At first, developed Lyapunov model reference adaptive feedback linearization method accompanied by indirect space vector control is applied for extraction maximum energy from variable speed system. Then, fuzzy logic controller designed the mentioned purpose its performance compared with proposed controller. For meeting more load demands, integrated turbine. In addition, storage are combined as backup to satisfy demand under all conditions. A supervisory order manage between captured turbine/solar arrays, consumed energies load, dump state charge (SOC), generated microturbine. Dynamic modeling accomplished MATLAB Simulink™ 7.2.