X‐Ray Measurements of Faulting in Ag–Pd Alloys

作者: P. Rama Rao , K. Krishna Rao

DOI: 10.1063/1.1655801

关键词:

摘要: A detailed study of x‐ray line broadening has been made in severely cold‐worked filings pure Pd and five Ag–Pd alloys containing 20, 40, 60, 75, 80 wt.% Pd. Debye‐Scherrer shapes recorded a proportional counter diffractometer have analyzed both by Fourier integral breadth methods for the evaluation effective particle sizes (De)hkl rms strains (〈e2〉hkl1/2). It found that 〈e2〉hkl1/2 are anisotropic vary little with composition. The importance faulting particle‐size could also be clearly observed. intrinsic fault densities (α) estimated from peak shifts, although small, show marked variation solute content. Following Otte's analysis, energies (γ) deduced using measured α, 〈e2〉hkl1/2, available shear modulus values. γ values thus arrived at compared those obtained these Harris et al. texture method. was concluded interaction d electrons ...

参考文章(28)
J. A. Rayne, Elastic Constants of Palladium from 4.2-300°K Physical Review. ,vol. 118, pp. 1545- 1549 ,(1960) , 10.1103/PHYSREV.118.1545
J W Christian, J Spreadborough, Stacking Faults and Dislocations in Copper-Aluminium and Cobalt-Nickel Alloys Proceedings of the Physical Society. Section B. ,vol. 70, pp. 1151- 1161 ,(1957) , 10.1088/0370-1301/70/12/306
T. E. Mitchell, S. S. Hecker, R. L. Smialek, Dislocation Pile-ups in Anisotropic Crystals Physica Status Solidi B-basic Solid State Physics. ,vol. 11, pp. 585- 594 ,(1965) , 10.1002/PSSB.19650110210
B. E. Warren, B. L. Averbach, The Separation of Stacking Fault Broadening in Cold‐Worked Metals Journal of Applied Physics. ,vol. 23, pp. 1059- 1059 ,(1952) , 10.1063/1.1702352
M. S. Paterson, X‐Ray Diffraction by Face‐Centered Cubic Crystals with Deformation Faults Journal of Applied Physics. ,vol. 23, pp. 805- 811 ,(1952) , 10.1063/1.1702312
R. P. I. Adler, C. N. J. Wagner, X‐Ray Diffraction Study of the Effects of Solutes on the Occurrence of Stacking Faults in Silver‐Base Alloys Journal of Applied Physics. ,vol. 33, pp. 3451- 3458 ,(1962) , 10.1063/1.1702428
BE Warren, X-Ray Measurement of Twin Faulting in Face-centred Cubic Metals Australian Journal of Physics. ,vol. 13, pp. 384- 390 ,(1960) , 10.1071/PH600384A
A. Papoulis, Method of Correction for the α1 α2 Doublet in the X‐Ray Diffraction Lines Review of Scientific Instruments. ,vol. 26, pp. 423- 426 ,(1955) , 10.1063/1.1771316