Smart materials applications for pediatric cardiovascular devices.

作者: Daniel S Levi , Nick Kusnezov , Gregory P Carman

DOI: 10.1203/PDR.0B013E31816A9D18

关键词:

摘要: "Smart Materials" are materials that change their shape, color, or size in response to an externally applied stimulus. While smart have already made a tremendous impact on our lives through applications liquid crystal displays, headphones, fuel injection systems, flexible cell phone antennas, and many other commercial products, they also the potential help pediatric patients. This review focuses with present of shape memory alloys, piezoelectric materials, relatively newer class called magnetostrictive ferromagnetic alloys design cardiovascular devices.

参考文章(43)
Ziyad M. Hijazi, Gianfranco Butera, Mario Carminati, Roberta Margherita Bini, Massimo Chessa, Sandra Giusti, Qi Ling Cao, Transcatheter closure of congenital and acquired muscular ventricular septal defects using the Amplatzer device. Journal of Invasive Cardiology. ,vol. 14, pp. 322- 327 ,(2002)
Zhong-Dong Du, Ziyad M Hijazi, Charles S Kleinman, Norman H Silverman, Kinley Larntz, Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. Journal of the American College of Cardiology. ,vol. 39, pp. 1836- 1844 ,(2002) , 10.1016/S0735-1097(02)01862-4
KASJA RABE, HORST SIEVERT, Carotid artery stenting: state of the art. Journal of Interventional Cardiology. ,vol. 17, pp. 417- 426 ,(2004) , 10.1111/J.1540-8183.2004.04085.X
Alberto Cremonesi, Carlo Setacci, Angelo Bignamini, Leonardo Bolognese, Francesco Briganti, Germano Di Sciascio, Domenico Inzitari, Gaetano Lanza, Luciano Lupattelli, Salvatore Mangiafico, Carlo Pratesi, Bernard Reimers, Stefano Ricci, Gianmarco de Donato, Ugo Ugolotti, Augusto Zaninelli, Gian Franco Gensini, Carotid Artery Stenting First Consensus Document of the ICCS-SPREAD Joint Committee Stroke. ,vol. 37, pp. 2400- 2409 ,(2006) , 10.1161/01.STR.0000236101.09480.B7
Ken K. Ho, Gregory P. Carman, Sputter deposition of NiTi thin film shape memory alloy using a heated target Thin Solid Films. ,vol. 370, pp. 18- 29 ,(2000) , 10.1016/S0040-6090(00)00947-0
Lenka L. Stepan, Daniel S. Levi, Gregory P. Carman, A Thin Film Nitinol Heart Valve Journal of Biomechanical Engineering. ,vol. 127, pp. 915- 918 ,(2005) , 10.1115/1.2049311
S. J. Murray, M. Marioni, S. M. Allen, R. C. O’Handley, T. A. Lograsso, 6% magnetic-field-induced strain by twin-boundary motion in ferromagnetic Ni–Mn–Ga Applied Physics Letters. ,vol. 77, pp. 886- 888 ,(2000) , 10.1063/1.1306635
A. Doll, M. Wischke, H.-J. Schrag, A. Geipel, F. Goldschmidtboeing, P. Woias, Characterization of active silicon microvalves with piezoelectric membrane actuators Microelectronic Engineering. ,vol. 84, pp. 1202- 1206 ,(2007) , 10.1016/J.MEE.2007.01.034
Ole Jakob Elle, Steinar Halvorsen, Martin Gunnar Gulbrandsen, Lars Aurdal, Andre Bakken, Eigil Samset, Harald Dugstad, Erik Fosse, Early recognition of regional cardiac ischemia using a 3-axis accelerometer sensor. Physiological Measurement. ,vol. 26, pp. 429- 440 ,(2005) , 10.1088/0967-3334/26/4/009
A. Lorber, A. Z. Gazit, A. Khoury, Y. Schwartz, F. Freudental, Percutaneous transaortic occlusion of patent ductus arteriosus using a new versatile angiographic and delivery catheter. Pediatric Cardiology. ,vol. 24, pp. 482- 483 ,(2003) , 10.1007/S00246-002-0235-Z