Interslice leakage artifact reduction technique for simultaneous multislice acquisitions

作者: Stephen F. Cauley , Jonathan R. Polimeni , Himanshu Bhat , Lawrence L. Wald , Kawin Setsompop

DOI: 10.1002/MRM.24898

关键词:

摘要: Purpose Controlled aliasing techniques for simultaneously acquired EPI slices have been shown to significantly increase the temporal efficiency both diffusion-weighted imaging (DWI) and fMRI studies. The “slice-GRAPPA” (SG) method has widely used reconstruct such data. We investigate robust optimization SG ensure image reconstruction accuracy through a reduction of leakage artifacts.

参考文章(16)
Steen Moeller, Essa Yacoub, Cheryl A. Olman, Edward Auerbach, John Strupp, Noam Harel, Kâmil Uğurbil, Multiband Multislice GE-EPI at 7 Tesla, With 16-Fold Acceleration Using Partial Parallel Imaging With Application to High Spatial and Temporal Whole-Brain FMRI Magnetic Resonance in Medicine. ,vol. 63, pp. 1144- 1153 ,(2010) , 10.1002/MRM.22361
Felix A. Breuer, Martin Blaimer, Robin M. Heidemann, Matthias F. Mueller, Mark A. Griswold, Peter M. Jakob, Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magnetic Resonance in Medicine. ,vol. 53, pp. 684- 691 ,(2005) , 10.1002/MRM.20401
Timothy G. Reese, Thomas Benner, Ruopeng Wang, David A. Feinberg, Van J. Wedeen, Halving imaging time of whole brain diffusion spectrum imaging and diffusion tractography using simultaneous image refocusing in EPI Journal of Magnetic Resonance Imaging. ,vol. 29, pp. 517- 522 ,(2009) , 10.1002/JMRI.21497
Martin Blaimer, Felix A. Breuer, Nicole Seiberlich, Matthias F. Mueller, Robin M. Heidemann, Vladimir Jellus, Graham Wiggins, Lawrence L. Wald, Mark A. Griswold, Peter M. Jakob, Accelerated volumetric MRI with a SENSE/GRAPPA combination. Journal of Magnetic Resonance Imaging. ,vol. 24, pp. 444- 450 ,(2006) , 10.1002/JMRI.20632
T. Jaermann, G. Crelier, K.P. Pruessmann, X. Golay, T. Netsch, A.M.C van Muiswinkel, S. Mori, P.C.M. van Zijl, A. Valavanis, S. Kollias, P. Boesiger, SENSE‐DTI at 3 T Magnetic Resonance in Medicine. ,vol. 51, pp. 230- 236 ,(2004) , 10.1002/MRM.10707
Martyn N.J. Paley, Kuan J. Lee, James M. Wild, Paul D. Griffiths, Elspeth H. Whitby, Simultaneous parallel inclined readout image technique Magnetic Resonance Imaging. ,vol. 24, pp. 557- 562 ,(2006) , 10.1016/J.MRI.2005.12.019
Peter R. Bannister, Peter R. Bannister, Michael Brady, Mark Jenkinson, Stephen M. Smith, IMPROVED OPTIMIZATION FOR THE ROBUST AND ACCURATE LINEAR REGISTRATION AND MOTION CORRECTION OF BRAIN IMAGES NeuroImage. ,vol. 17, pp. 825- 841 ,(2002) , 10.1016/S1053-8119(02)91132-8
Kawin Setsompop, Borjan A. Gagoski, Jonathan R. Polimeni, Thomas Witzel, Van J. Wedeen, Lawrence L. Wald, Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magnetic Resonance in Medicine. ,vol. 67, pp. 1210- 1224 ,(2012) , 10.1002/MRM.23097
Boris Keil, James N. Blau, Stephan Biber, Philipp Hoecht, Veneta Tountcheva, Kawin Setsompop, Christina Triantafyllou, Lawrence L. Wald, A 64-channel 3T array coil for accelerated brain MRI Magnetic Resonance in Medicine. ,vol. 70, pp. 248- 258 ,(2013) , 10.1002/MRM.24427
David A. Feinberg, Timothy G. Reese, Van J. Wedeen, Simultaneous echo refocusing in EPI Magnetic Resonance in Medicine. ,vol. 48, pp. 1- 5 ,(2002) , 10.1002/MRM.10227