Comparison between mixed and laminar airflow systems in operating rooms and the influence of human factors: Experiences from a Swedish orthopedic center

作者: Annette Erichsen Andersson , Max Petzold , Ingrid Bergh , Jón Karlsson , Bengt I. Eriksson

DOI: 10.1016/J.AJIC.2014.02.001

关键词:

摘要: Comparison between mixed and laminar airflow systems in operating rooms the influence of human factors : Experiences from a Swedish orthopedic center

参考文章(32)
GERTRUDE KAY MCFARLAND, Nursing research : principles and methods American Journal of Nursing. ,vol. 87, pp. 1515- 1518 ,(1987) , 10.1097/00000446-198711000-00035
E A Salvati, R P Robinson, S M Zeno, B L Koslin, B D Brause, P D Wilson, Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system. The Journal of Bone & Joint Surgery. ,vol. 64, pp. 525- 535 ,(1982) , 10.2106/00004623-198264040-00007
Julian W. Tang, Andre Nicolle, Jovan Pantelic, Christian A. Klettner, Ruikun Su, Petri Kalliomaki, Pekka Saarinen, Hannu Koskela, Kari Reijula, Panu Mustakallio, David K. W. Cheong, Chandra Sekhar, Kwok Wai Tham, Different Types of Door-Opening Motions as Contributing Factors to Containment Failures in Hospital Isolation Rooms PLOS ONE. ,vol. 8, ,(2013) , 10.1371/JOURNAL.PONE.0066663
P. Gastmeier, A.-C. Breier, C. Brandt, Influence of laminar airflow on prosthetic joint infections: a systematic review Journal of Hospital Infection. ,vol. 81, pp. 73- 78 ,(2012) , 10.1016/J.JHIN.2012.04.008
Zhang Rui, Tu Guangbei, Ling Jihong, Study on biological contaminant control strategies under different ventilation models in hospital operating room Building and Environment. ,vol. 43, pp. 793- 803 ,(2008) , 10.1016/J.BUILDENV.2007.01.018
Raymond J. Lynch, Michael J. Englesbe, Lisa Sturm, Amira Bitar, Karn Budhiraj, Sandeep Kolla, Yuliya Polyachenko, Mary G. Duck, Darrell A. Campbell, Measurement of Foot Traffic in the Operating Room: Implications for Infection Control American Journal of Medical Quality. ,vol. 24, pp. 45- 52 ,(2009) , 10.1177/1062860608326419
S. Dharan, D. Pittet, Environmental controls in operating theatres. Journal of Hospital Infection. ,vol. 51, pp. 79- 84 ,(2002) , 10.1053/JHIN.2002.1217
Eric B. Smith, Ibrahim J. Raphael, Mitchell G. Maltenfort, Sittisak Honsawek, Kyle Dolan, Elizabeth A. Younkins, The effect of laminar air flow and door openings on operating room contamination. Journal of Arthroplasty. ,vol. 28, pp. 1482- 1485 ,(2013) , 10.1016/J.ARTH.2013.06.012
Anna Stefánsdóttir, Daniel Johansson, Kaj Knutson, Lars Lidgren, Otto Robertsson, Microbiology of the infected knee arthroplasty: report from the Swedish Knee Arthroplasty Register on 426 surgically revised cases. Scandinavian Journal of Infectious Diseases. ,vol. 41, pp. 831- 840 ,(2009) , 10.3109/00365540903186207