作者: Zhenjun Ma , A.K. Pandey , Haoshan Ren , K. Chopra , V.V. Tyagi
DOI: 10.1016/J.EST.2021.102232
关键词:
摘要: Abstract In this study, exergy, energy, enviroeconomic & exergoeconomic analysis of evacuated tube collector with/without latent heat storage material has been done for different flow rates i.e. 0.13, 0.26, 0.40 0.46 LPM. manuscript, palmitic acid used as a material. The was filled in the annuls between absorber pipe and termed integrated system while another based tested without system. results experimental investigation revealed that daily thermal exergy efficiencies increased range 36-44% 28-35% respectively comparison to storage. Furthermore, mitigated 21-28 tCO2/lifetime 6-8 on environmental exergoenvironmental approaches respectively. Whereas, 14-19 4-6 approach storage, revenue generated by with found be 95-112 $/lifetime 22-25 higher energy Overall, continuous solar water heating most promising selected water.