Fructosamine and glycated hemoglobin as indices of glycemic control in patients with liver cirrhosis.

作者: Alessandro Cristani , Roberta Pentore , Ezio Ventura , Giorgio Cioni , Cristina Mussini

DOI: 10.1007/BF02900711

关键词:

摘要: Glucose intolerance often occurs in liver cirrhosis; therefore a long-term control of plasma glucose levels appears to be important. For this purpose glycated hemoglobin A (HbA1c) determination is proposed as suitable method, while no data are available on fructosamine test. In 98 cirrhotic patients serum and HbA1c were compared with those normal controls among grouped non glucose-intolerant insulin-dependent (NIDDM) or diabetes mellitus (IDDM). The mean values glycemic significantly lower than normal, only few IDDM NIDDM showed high HbA1c, indicating that underestimated these patients. On the contrary, average higher nondiabetic patients, but they nondiabetics, 72% 85% had upper value. conclusion, diabetic cirrhosis seems more test for monitoring blood levels.

参考文章(16)
R. Dolhofer, A. St�dele, O. H. Wieland, [Clinical and biochemical studies on the significance and formation of hemoglobins AIc and AIa+b in diabetes mellitus]. Journal of Molecular Medicine. ,vol. 55, pp. 945- 954 ,(1977) , 10.1007/BF01479226
D Lloyd, J Marples, Simple colorimetry of glycated serum protein in a centrifugal analyzer. Clinical Chemistry. ,vol. 30, pp. 1686- 1688 ,(1984) , 10.1093/CLINCHEM/30.10.1686
J R Baker, P A Metcalf, R N Johnson, D Newman, P Rietz, Use of protein-based standards in automated colorimetric determinations of fructosamine in serum. Clinical Chemistry. ,vol. 31, pp. 1550- 1554 ,(1985) , 10.1093/CLINCHEM/31.9.1550
M P Van Dieijen-Visser, C Seynaeve, P J Brombacher, Influence of variations in albumin or total-protein concentration on serum fructosamine concentration. Clinical Chemistry. ,vol. 32, pp. 1610- 1610 ,(1986) , 10.1093/CLINCHEM/32.8.1610
Y S Lim, M J Staley, Measurement of plasma fructosamine evaluated for monitoring diabetes. Clinical Chemistry. ,vol. 31, pp. 731- 733 ,(1985) , 10.1093/CLINCHEM/31.5.731
S Rodriguez-Segade, S Lojo, M F Camiña, J M Paz, R Del Río, Effects of various serum proteins on quantification of fructosamine. Clinical Chemistry. ,vol. 35, pp. 134- 138 ,(1989) , 10.1093/CLINCHEM/35.1.134
F San-Gil, G M Schier, R G Moses, I E Gan, Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer. Clinical Chemistry. ,vol. 31, pp. 2005- 2006 ,(1985) , 10.1093/CLINCHEM/31.12.2005
J R Baker, J P O'Connor, P A Metcalf, M R Lawson, R N Johnson, Clinical usefulness of estimation of serum fructosamine concentration as a screening test for diabetes mellitus. BMJ. ,vol. 287, pp. 863- 867 ,(1983) , 10.1136/BMJ.287.6396.863