Influence of Slag Cement on the Permeability of Concrete for Biological Shielding Structures

作者: Daria Jóźwiak-Niedźwiedzka , Mariusz Dąbrowski , Karolina Bogusz , Michał A. Glinicki

DOI: 10.3390/EN13174582

关键词:

摘要: Durability of concrete designed for radiation shielding structures is an important issue in nuclear power plant safety. An investigation the permeability containing heavyweight aggregates and water-bearing was performed with respect to gaseous liquid media. Mix design developed using Portland slag cement, crushed magnetite serpentine aggregate. The use cement resulted substantial improvement compressive strength comparison concrete. application found reduce chloride ingress, regardless special aggregate use. coefficient migration within range 5 ÷ 8 × 10−12 m2/s 17 25 concrete, respectively. At same time, carbonation depth increased twice However, maximum after one year exposure 1% CO2 only 14 mm 7 reference total pore volume evaluated mercury intrusion porosimetry influenced by type used. It shown that various contents achieved smallest volume. While coarse caused increase

参考文章(32)
G Nahas, J M Torrenti, Durability and Safety of Concrete Structures in the Nuclear Context Sixth International Conference on Concrete under Severe Conditions: Environment and LoadingCentro de Investigacion y de Estudios Avanzados del IPN, Unidad MeridaConsejo Nacional de Ciencia y Tecnologia, CONACyTUniversidad Autonoma de YucatanGobierno del Estado de YucatanH Ayuntamiento de la Ciudad de MeridaH Ayuntamiento de la Ciudad de ProgresoAsociacion Latinoamericana de Control de Calidad, Patologia y Recuperacion de la Construccion, ALCONPAT MexicoCEMEX Concretos SA de CVWR GRACE Holdings SA de CVPENMAR SA de CVSIKA Mexicana SA de CVBASF Mexicana SA de CV. ,(2010)
İ. Akkurt, C. Başyiğit, A. Akkaş, Ş. Kılınçarslan, B. Mavi, K. Günoğlu, Determination of Some Heavyweight Aggregate Half Value Layer Thickness Used for Radiation Shielding Acta Physica Polonica A. ,vol. 121, pp. 138- 140 ,(2012) , 10.12693/APHYSPOLA.121.138
Elżbieta Horszczaruk, Paweł Sikora, Paweł Zaporowski, Mechanical Properties of Shielding Concrete with Magnetite Aggregate Subjected to High Temperature Procedia Engineering. ,vol. 108, pp. 39- 46 ,(2015) , 10.1016/J.PROENG.2015.06.117
Zbigniew Giergiczny, Michal A. Glinicki, Marcin Sokołowski, Marek Zielinski, Air void system and frost-salt scaling of concrete containing slag-blended cement Construction and Building Materials. ,vol. 23, pp. 2451- 2456 ,(2009) , 10.1016/J.CONBUILDMAT.2008.10.001
K. Sakr, E. EL-Hakim, Effect of high temperature or fire on heavy weight concrete properties Cement and Concrete Research. ,vol. 35, pp. 590- 596 ,(2005) , 10.1016/J.CEMCONRES.2004.05.023
Hanifi Binici, Durability of heavyweight concrete containing barite International Journal of Materials Research. ,vol. 101, pp. 1052- 1059 ,(2010) , 10.3139/146.110360
S. Yousef, M. AlNassar, B. Naoom, S. Alhajali, M.H. Kharita, Heat effect on the shielding and strength properties of some local concretes Progress in Nuclear Energy. ,vol. 50, pp. 22- 26 ,(2008) , 10.1016/J.PNUCENE.2007.10.003
Andreas Leemann, Roman Loser, Beat Münch, Influence of cement type on ITZ porosity and chloride resistance of self-compacting concrete Cement & Concrete Composites. ,vol. 32, pp. 116- 120 ,(2010) , 10.1016/J.CEMCONCOMP.2009.11.007