作者: Z M Ding , L G Chen , F R Sun
DOI: 10.1179/1743967112Z.00000000032
关键词:
摘要: A model of an irreversible energy selective electron (ESE) heat pump with leakage is established in this paper. The general expressions for heating load and coefficient performance (COP) the ESE maximum operation regime intermediate are derived respectively. optimum performances these two different regimes analysed by detailed numerical examples. characteristic curves COP versus considering parabolic-like ones, will approach a fixed value as increases. This due to fact that electrons contribute positively pumping all transmitted through filter regime. without intermediated be below unity heating...