Electrochemical detection of bovine immunoglobulins G to determine passive transfer of antibodies to calves.

作者: Caoimhe Robinson , Niamh Creedon , Riona Sayers , Emer Kennedy , Alan O'Riordan

DOI: 10.1039/D0AY00194E

关键词:

摘要: Bovine antibodies, such as immunoglobulin G (IgG), cannot pass the placental barrier and are not transferred from mother to foetus, in utero. Instead a calf must absorb antibodies following ingestion of colostrum postpartum. Failure Passive Transfer (FPT) is condition that predisposes calves development disease increases risk mortality. Thus, continuous early monitoring IgG absorption calf, within first 6 12 hours life, imperative allow faster treatment prevent FPT. In this paper, we present label-free impedimetric immunosensor device for bovine serum demonstrate its suitability determine FPT new-born calves. The developed sensors were challenged discriminate between new born sera, both pre- post-colostrum feeding, demonstrated efficient detection under 15 minutes. Such could enable rapid determination FPT, thereby improving calves' vitality survival rate.

参考文章(22)
Diming Zhang, Yanli Lu, Qian Zhang, Lei Liu, Shuang Li, Yao Yao, Jing Jiang, Gang Logan Liu, Qingjun Liu, Protein detecting with smartphone-controlled electrochemical impedance spectroscopy for point-of-care applications Sensors and Actuators B-chemical. ,vol. 222, pp. 994- 1002 ,(2016) , 10.1016/J.SNB.2015.09.041
L.J. Bush, M.A. Aguilera, G.D. Adams, E.W. Jones, Absorption of Colostral Immnunoglobulins by Newborn Dairy Calves Journal of Dairy Science. ,vol. 54, pp. 1547- 1549 ,(1971) , 10.3168/JDS.S0022-0302(71)86063-0
Ying Wan, Yan Su, Xinhua Zhu, Gang Liu, Chunhai Fan, Development of electrochemical immunosensors towards point of care diagnostics. Biosensors and Bioelectronics. ,vol. 47, pp. 1- 11 ,(2013) , 10.1016/J.BIOS.2013.02.045
Kuangwen Hsieh, B. Scott Ferguson, Michael Eisenstein, Kevin W. Plaxco, H. Tom Soh, Integrated Electrochemical Microsystems for Genetic Detection of Pathogens at the Point of Care Accounts of Chemical Research. ,vol. 48, pp. 911- 920 ,(2015) , 10.1021/AR500456W
Cuie Wang, Qin Yan, Hong-Bo Liu, Xiao-Hui Zhou, Shou-Jun Xiao, Different EDC/NHS activation mechanisms between PAA and PMAA brushes and the following amidation reactions. Langmuir. ,vol. 27, pp. 12058- 12068 ,(2011) , 10.1021/LA202267P
Robert V. Vogt, Donald L. Phillips, L. Omar Henderson, Wanda Whitfield, Francis W. Spierto, Quantitative differences among various proteins as blocking agents for ELISA microtiter plates. Journal of Immunological Methods. ,vol. 101, pp. 43- 50 ,(1987) , 10.1016/0022-1759(87)90214-6
Dusty M. Weaver, Jeff W. Tyler, David C. VanMetre, Douglas E. Hostetler, George M. Barrington, Passive transfer of colostral immunoglobulins in calves. Journal of Veterinary Internal Medicine. ,vol. 14, pp. 569- 577 ,(2000) , 10.1111/J.1939-1676.2000.TB02278.X
L.J. Bush, T.E. Staley, Absorption of Colostral Immunoglobulins in Newborn Calves Journal of Dairy Science. ,vol. 63, pp. 672- 680 ,(1980) , 10.3168/JDS.S0022-0302(80)82989-4
Joseph Wang, Electrochemical biosensors: Towards point-of-care cancer diagnostics Biosensors and Bioelectronics. ,vol. 21, pp. 1887- 1892 ,(2006) , 10.1016/J.BIOS.2005.10.027
Wijitar Dungchai, Orawon Chailapakul, Charles S. Henry, Electrochemical Detection for Paper-Based Microfluidics Analytical Chemistry. ,vol. 81, pp. 5821- 5826 ,(2009) , 10.1021/AC9007573