Postblink changes in the ocular modulation transfer function measured by a double-pass method.

作者: Robert Monte´s-Mico´ , Jorge L. Alio´ , W. Neil Charman

DOI: 10.1167/IOVS.05-0609

关键词:

摘要: PURPOSE. To examine the temporal changes in modulation transfer function (MTF) of eye after a blink. METHODS. The distance MTF 5-mm pupil was derived from double-pass retinal images 20 healthy young subjects at various intervals blink (1 second up to 15 seconds). Such measurements include effects wavefront aberration, scattered light, and errors focus are thus more relevant real life than estimates based on alone. RESULTS. Optimal by variety criteria found some 6 seconds CONCLUSIONS. Inclusion stray light does not affect finding that optimal image quality occurs time It appear loss optical is trigger normal blinking.

参考文章(44)
Charman Wn, Jennings Ja, The optical quality of the monochromatic retinal image as a function of focus. The British journal of physiological optics. ,vol. 31, pp. 119- ,(1976)
Smirnov Ms, Measurement of the wave aberration of the human eye Biofizika. ,vol. 6, pp. 687- 703 ,(1961)
Robert Montés-Micó, Araceli Cáliz, Jorge L Alió, Wavefront analysis of higher order aberrations in dry eye patients. Journal of Refractive Surgery. ,vol. 20, pp. 243- 247 ,(2004) , 10.3928/1081-597X-20040501-08
János Németh, Béla Erdélyi, Béla Csákány, Péter Gáspár, Alexandros Soumelidis, Ferenc Kahlesz, Zsolt Lang, None, High-speed videotopographic measurement of tear film build-up time. Investigative Ophthalmology & Visual Science. ,vol. 43, pp. 1783- 1790 ,(2002)
W. T. Welford, Aberrations of optical systems ,(1986)
Larry N. Thibos, Carolyn Begley, Arthur Bradley, Ron Tutt, Optical and visual impact of tear break-up in human eyes Investigative Ophthalmology & Visual Science. ,vol. 41, pp. 4117- 4123 ,(2000)
Chris A. Johnson, Effects of luminance and stimulus distance on accommodation and visual resolution. Journal of the Optical Society of America. ,vol. 66, pp. 138- 142 ,(1976) , 10.1364/JOSA.66.000138
D. A. Benedetto, T. E. Clinch, P. R. Laibson, In vivo observation of tear dynamics using fluorophotometry. Archives of Ophthalmology. ,vol. 102, pp. 410- 412 ,(1984) , 10.1001/ARCHOPHT.1984.01040030328030
P Cho, Tear break‐up time: clinical procedures and their effects Ophthalmic and Physiological Optics. ,vol. 18, pp. 319- 324 ,(1998) , 10.1016/S0275-5408(98)00014-3
W.T. Welford, Optical Instruments and Techniques Journal of Modern Optics. ,vol. 16, pp. 665- 668 ,(1969) , 10.1080/713818207